BackgroundRandom safety audits (RSA) are a safety tool enabling prevention of adverse events, but they have not been widely used in hospitals. The aim of this study was to use RSAs to assess and compare the frequency of appropriate use of infusion pump safety systems in a Neonatal Intensive Care Unit (NICU) before and after quality improvement interventions and to analyse the intravenous medication programming data.MethodsProspective, observational study comparing the frequency of appropriate use of Alaris® CC smart pumps through RSAs over two periods, from 1 January to 31 December 2012 and from 1 November 2014 to 31 January 2015. Appropriate use was defined as all evaluated variables being correctly programmed into the same device. Between the two periods they were established interventions to improve the use of pumps. The information recorded at the pumps with the new security system, also extracted for one year.ResultsFifty-two measurements were collected during the first period and 160 measurements during the second period. The frequency of appropriate use was 73.13 % (117/160) in the second period versus 0 % (0/52) in the first period (p < 0.0001). Information was recorded on 44,924 infusions; in 46.03 % (20,680/44,924) of cases the drug name was recorded. In 2.5 % (532/20,680) of cases there was an attempt to exceed the absolute limit.ConclusionsRandom Safety Audits were a very useful tool for detecting inappropriate use of pumps in the NICU. The improvement strategies were effective for improving appropriate use and programming of the intravenous medication infusion pumps in our NICU.
An epidemiological, multicenter, noninterventional, observational case-control study was conducted to describe the performance of serum beta-d-glucan (BDG) and Candida PCR in blood, serum, and sterile samples for the diagnosis of invasive candidiasis (IC) in very-low-birth-weight (VLBW) preterm neonates and to compare these techniques with culture of samples from blood and other sterile sites. Seventeen centers participated in the study, and the number of episodes analyzed was 159. A total of 9 episodes of IC from 9 patients (7 confirmed and 2 probable) and 150 episodes of suspected sepsis from 117 controls were identified. The prevalence of IC was 5.7% (95% confidence interval [95% CI], 2.1 to 9.3). The mortality was significantly higher in episodes of IC (44.4%) than in the non-IC episodes (11.1%, P < 0.01). The sensitivity and specificity of the PCR performed on blood/serum samples were 87.5% and 81.6%, respectively. The sensitivity and specificity of the BDG results were lower (75.0% and 64.6%). For cases with negative culture results, the PCR and the BDG results were positive in 27 (17.4%) and 52 (33.5%) episodes, respectively. The presence of multiorgan failure, improvement with empirical antifungal therapy, thrombocytopenia, and Candida colonization were significantly associated (P < 0.01) with PCR or BDG positivity regardless of the results of the cultures. Serum BDG analysis and Candida PCR could be used as complementary diagnostic techniques to detect IC in VLBW neonates.
Background. Random safety audits (RSAs) are a safety tool but have not been widely used in hospitals.
Objectives. To determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used. Methods. A prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU) during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device.
Results. A total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12–3.06, p = 0.01), and during the late shift (3 pm to 10 pm), OR 1.59 (1.03–2.4, p = 0.03). Conclusions. Equipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.