Patients with IVNC-DCM had greater LV reverse remodelling after CRT than patients with DCM. The greater the area of non-compaction (higher number of IVNC segments) the greater the chance of achieving CRT response and greater LV reverse remodelling.
Exercise intraventricular dyssynchrony assessed by exercise TDI ECHO is a strong independent predictor of CRT response. It could be used to select candidates for CRT, thus reducing ineffective implantations of biventricular pacemakers.
Background-Phrenic stimulation (PS) may hinder left ventricular (LV) pacing. We prospectively observed its prevalence in consecutive patients with cardiac resynchronization therapy (CRT) devices. Methods and Results-In the years 2003 to 2006, 197 patients received a CRT device. PS and LV threshold measurements were carried out at implantation and at 6-month follow-up. LV reverse remodeling was assessed by echocardiography before implantation and at follow-up. LV lead placement was lateral/posterolateral in 86% of patients. Both PS and LV reverse remodeling occurred most frequently at the lateral/posterolateral LV pacing sites (PϽ0.001). PS was detected in 73 (37%) of patients and was clinically relevant in 41 (22%). The detection of PS at implantation had a poor sensitivity, as it occurred only in left lateral or sitting position in 27 patients. Ten patients (5%) underwent repeated surgery and 4 (2%) had their CRT turned off because of PS. At follow-up, we could manage PS noninvasively in 32 patients with a small PS-LV threshold difference: in 20 by cathode programmability (3 also thanks to automatic management of LV output) and in 12 (without cathode programmability) by programming the LV output as threshold ϩ1 V. Conclusions-PS may seriously hinder CRT. A bipolar LV lead and cathode programmability are mandatory to avoid PS by changing the LV pacing vector at target sites for CRT. LV stability at target sites despite PS should also be pursued by these means. The automatic adjustment of LV pacing output is complementary in patients with a small PS-LV threshold difference. (Circ Arrhythmia Electrophysiol. 2009;2:402-410.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.