There is intense clinical interest in the potential effects of platelet-rich plasma (PRP) for the treatment of osteoarthritis (OA). This study tested the hypotheses that (i) "lower" levels of the inflammatory mediators (IMs), interleukin-1β, and tumor necrosis factor α (TNF-α) and (ii) "higher" levels of the growth factors (GFs), insulin-like growth factor 1, and transforming growth factor β1 within leukocyte-poor PRP correlate with more favorable chondrocyte and macrophage responses in vitro. Samples were collected from 10 "healthy" young male (23-33 years old) human subjects (H-PRP) and nine older (62-85 years old) male patients with severe knee OA (OA-PRP). The samples were separated into groups of "high" or "low" levels of IM and GF based on multiplex cytokine and enzyme-linked immunosorbent assay data. Three-dimensional (3D) alginate bead chondrocyte cultures and monocyte-derived macrophage cultures were treated with 10% PRP from donors in different groups. Gene expression was analyzed by quantitative polymerase chain reaction. Contrary to our hypotheses, the effect of PRP on chondrocytes and macrophages was mainly influenced by the age and disease status of the PRP donor as opposed to the IM or GF groupings. While H-PRP showed similar effects on expression of chondrogenic markers (Col2a1 and Sox9) as the negative control group (p > 0.05), OA-PRP decreased chondrocyte expression of Col2a1 and Sox-9 messenger RNA by 40% and 30%, respectively (Col2a1, p = 0.015; Sox9, p = 0.037). OA-PRP also upregulated TNF-α and matrix metallopeptidase 9 (p < 0.001) gene expression in macrophages while H-PRP did not. This data suggests that PRP from older individuals with OA contain factors that may suppress chondrocyte matrix synthesis and promote macrophage inflammation in vitro.
Purpose Total knee arthroplasty is a successful procedure in treating subjects with end-stage knee osteoarthritis. The objective of this matched study was to evaluate subjective patient satisfaction and clinical and radiological outcomes in two groups of patients undergoing primary TKA using an identical third-generation design with different conformity in the polyethylene insert. Methods One hundred consecutive patients undergoing TKA because of knee osteoarthritis were randomized in two matched groups. Group A included 50 Posterior-Stabilized (PS) implants, while group B included 50 Medially Congruent (MC) implants. The surgical technique was identical: gap balancing in extension and measured resection in flexion; cruciate ligaments were always removed; the coronal alignment followed the mechanical axis and the tibial slope was set at 3° in the PS group and 5° in the MC. Oxford Knee Score (OKS) and Knee Society Score (KSS) were assessed preoperatively and at 2 year minimum follow-up. Two-sample T test statistical analysis was performed. Results All patients were available at final follow-up: there were no preoperative statistical differences between the two groups in the average preoperative ROM (PS 112°, MC 108°; n.s.), average preoperative KSS (PS 64.4, MC 63.7; n.s.), average preoperative OKS (PS 19.6; MC 19.0; n.s.), and average BMI (PS 34.40, MC 34.60; n.s.). At final follow-up, there were no statistical differences between the two groups in the average OKS (PS 40,5; MC 41.1; n.s.) and in the average KSS (PS 161,5, MC 165,7; n.s.). We found a statistically but not clinically significant difference at final ROM: the average maximum active flexion was 120° in the PS group and 123° in the MC group (s.s.). Conclusion This study evaluated two biomechanically different polyethylene inserts in the same TKA design, showing that reducing the level of intra-articular conformity had minimal effects on PROMs and objective short-term clinical results but a potentially beneficial effect on ROM. This study suggests that, once a satisfactory intra-operative stability is obtained, the minimal level of constraint should be used. Level of evidence III.
This study aimed to determine if changes in knee adduction moment (KAM) after 6 months of variable‐stiffness shoe wear are associated with changes in symptoms or serum levels of cartilage oligomeric matrix protein (COMP) following a mechanical stimulus in subjects with medial knee osteoarthritis (OA). Twenty‐five subjects were enrolled in the study and assigned a variable‐stiffness shoe, and 19 subjects completed the 6‐month follow‐up. At baseline and follow‐up subjects underwent gait analysis in control and variable‐stiffness shoes, completed Western Ontario and McMaster Universities (WOMAC) questionnaires, and serum COMP concentrations were measured immediately before, 3.5 and 5.5 hours after a 30‐minute walking activity. Relationships between changes in KAM (first peak and impulse) and changes in (a) COMP levels in response to the 30‐minute walking activity and (b) WOMAC scores from baseline to 6‐month follow‐up were assessed by Pearson correlation coefficients. Changes in first peak KAM were associated with changes in COMP levels 5.5 hours postactivity from baseline to follow‐up (R = .564, P = .045). Subjects with greater reductions in KAM had larger decreases in COMP (expressed as a percent of preactivity levels) at follow‐up. Subjects with greater reductions in KAM impulse had significantly greater improvements in WOMAC Pain (R = −.56, P = .015) and Function (R = −.52, P = .028) scores at follow‐up. The study results demonstrated the magnitude of reduction in the KAM wearing a variable‐stiffness shoe is associated with decreases in mechanically stimulated COMP levels and pain/function. This work suggests that interactions between COMP and joint loading during walking should be further investigated in future studies of treatment outcomes in OA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.