It is not uncommon for clinicians to encounter varying degrees of hepatic steatosis in patients undergoing resection for colorectal liver metastases (CRLM). Magnetic resonance imaging is currently the preferred investigation for identification and pre-operative planning of these patients. An objective assessment of liver quality and degree of steatosis is paramount for planning a safe resection, which is seldom provided by routine MRI sequences. We studied two patients who underwent an additional pre-operative multiparametric MRI scan (LiverMultiScanTM) as a part of an observational clinical trial (HepaT1ca, NCT03213314) to assess the quality of liver. Outcome was assessed in the form of post-hepatectomy liver failure. Both patients (Patient 1 and 2) had comparable pre-operative characteristics. Both patients were planned for an extended right hepatectomy with an estimated future liver remnant of approximately 30%. Conventional preoperative contrast MRI showed mild liver steatosis in both patients. Patient one developed post-hepatectomy liver failure leading to prolonged hospital stay compared to patient two who had uneventful post-operative course. Retrospective evaluation of multiparametric MRI scan revealed findings consistent with fibro-inflammatory disease and steatosis (cT1 829 ms, PDFF 14%) for patient 1 whereas patient two had normal parameters (cT1 735 ms, PDFF 2.4%). These findings corresponded with the resection specimen histology. Multiparametric MRI can objectively evaluate future liver health and volume which may help refine surgical decision-making and improve patient outcomes
Purpose
R2*, a measurement obtained using magnetic resonance imaging (MRI) can be used to estimate liver iron concentration (LIC). 3 T and 1.5 T scanners can be used but conversion of 3 T R2* to LIC is less well validated. In this study the aim was to compare 3 T-R2* LIC and 1.5 T-R2* LIC estimations to assess if they can be used interchangeably.
Methods
Thirty participants were scanned at both 1.5 T and 3 T. R2* was measured at both field strengths. 3 T R2* and 1.5 R2* were compared using linear regression and were converted to LIC using different calibration curves. Pearson’s rho and Intraclass Correlation Coefficients (ICCs) were used to assess correlation and agreement between 1.5 and 3 T LIC. Bland Altman plots were used to assess bias and limits of agreement.
Results
All 1.5 T and 3 T LIC comparisons gave Pearson’s rho of 0.99 (p < 0.001). ICC ranged from 0.83 (p = 0.005) to 0.96 (p < 0.001). Biases had magnitude of less than 0.2 mg/g dry weight.
Conclusion
Agreement and bias between 3 and 1.5 T-R2* LIC depended on the method used for conversion. There were instances when the agreement was excellent and bias was small, indicating that potentially 3 T-R2* LIC can be used alongside or instead of 1.5 T-R2* LIC but care needs to be taken over the conversion methods selected.
Trial registration number
Clinicaltrials.gov NCT03743272, 16 November 2018.
Graphical abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.