The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Despite the advent of non-fluoroscopic technology, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies over ablation interventions to device implantation. Moreover, many patients receive additional X-ray imaging, such as cardiac computed tomography and others. More and more complex procedures have the risk to increase the radiation exposure, both for the patients and the operators. The professional lifetime attributable excess cancer risk may be around 1 in 100 for the operators, the same as for a patient undergoing repetitive complex procedures. Moreover, recent reports have also hinted at an excess risk of brain tumours among interventional cardiologists. Apart from evaluating the need for and justifying the use of radiation to assist their procedures, physicians have to continuously explore ways to reduce the radiation exposure. After an introduction on how to quantify the radiation exposure and defining its current magnitude in electrophysiology compared with the other sources of radiation, this position paper wants to offer some very practical advice on how to reduce exposure to patients and staff. The text describes how customization of the X-ray system, workflow adaptations, and shielding measures can be implemented in the cath lab. The potential and the pitfalls of different non-fluoroscopic guiding technologies are discussed. Finally, we suggest further improvements that can be implemented by both the physicians and the industry in the future. We are confident that these suggestions are able to reduce patient and operator exposure by more than an order of magnitude, and therefore think that these recommendations are worth reading and implementing by any electrophysiological operator in the field.
The benefits of cardiac imaging are immense, and modern medicine requires the extensive and versatile use of a variety of cardiac imaging techniques. Cardiologists are responsible for a large part of the radiation exposures every person gets per year from all medical sources. Therefore, they have a particular responsibility to avoid unjustified and non-optimized use of radiation, but sometimes are imperfectly aware of the radiological dose of the examination they prescribe or practice. This position paper aims to summarize the current knowledge on radiation effective doses (and risks) related to cardiac imaging procedures. We have reviewed the literature on radiation doses, which can range from the equivalent of 1-60 milliSievert (mSv) around a reference dose average of 15 mSv (corresponding to 750 chest X-rays) for a percutaneous coronary intervention, a cardiac radiofrequency ablation, a multidetector coronary angiography, or a myocardial perfusion imaging scintigraphy. We provide a European perspective on the best way to play an active role in implementing into clinical practice the key principle of radiation protection that: 'each patient should get the right imaging exam, at the right time, with the right radiation dose'.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.