Mechanical analysis of movement plays an important role in clinical management of neurological and orthopedic conditions. There has been increasing interest in performing movement analysis in real-time, to provide immediate feedback to both therapist and patient. However, such work to date has been limited to single-joint kinematics and kinetics. Here we present a software system, named human body model (HBM), to compute joint kinematics and kinetics for a full body model with 44 degrees of freedom, in real-time, and to estimate length changes and forces in 300 muscle elements. HBM was used to analyze lower extremity function during gait in 12 able-bodied subjects. Processing speed exceeded 120 samples per second on standard PC hardware. Joint angles and moments were consistent within the group, and consistent with other studies in the literature. Estimated muscle force patterns were consistent among subjects and agreed qualitatively with electromyography, to the extent that can be expected from a biomechanical model. The real-time analysis was integrated into the D-Flow system for development of custom real-time feedback applications and into the gait real-time analysis interactive lab system for gait analysis and gait retraining.Electronic supplementary materialThe online version of this article (doi:10.1007/s11517-013-1076-z) contains supplementary material, which is available to authorized users.
Lower-extremity kinematics adapted to increased midsole hardness, surface stiffness, and running duration. Changes in limb posture at impact were interpreted as active adaptations that compensate for passive mechanical effects. The adaptations appeared to have the goal of minimizing metabolic cost at the expense of increased exposure to impact shock.
Abstract-Implanted functional electrical stimulation (FES) systems for walking are experimentally available to individuals with incomplete spinal cord injury (SCI); however, data on short-term therapeutic and functional outcomes are limited. The goal of this study was to quantify therapeutic and functional effects of an implanted FES system for walking after incomplete cervical SCI. After robotic-assisted treadmill training and overground gait training maximized his voluntary function, an individual with incomplete SCI (American Spinal Injury Association grade C, cervical level 6-7) who could stand volitionally but not step was surgically implanted with an 8-channel receiver stimulator and intramuscular electrodes. Electrodes were implanted bilaterally, recruiting iliopsoas, vastus intermedius and lateralis, tensor fasciae latae, tibialis anterior, and peroneus longus muscles. Twelve weeks of training followed limited activity post-surgery. Customized stimulation patterns addressed gait deficits via an external control unit. The system was well-tolerated and reliable. After the 12-week training, maximal walking distance increased (from 14 m to 309 m), maximal walking speed was 10 times greater (from 0.02 m/s to 0.20 m/s), and physiological cost index was 5 times less (from 44.4 beats/m to 8.6 beats/m). Voluntary locomotor function was unchanged. The implanted FES system was welltolerated, reliable, and supplemented function, allowing the participant limited community ambulation. Physiological effort decreased and maximal walking distance increased dramatically over 12 weeks.
a b s t r a c tThis paper discusses the CO 2 footprint of California's drought during 2012-2014. We show that California drought significantly increased CO 2 emissions of the energy sector by around 22 million metric tons, indicating 33% increase in the annual CO 2 emissions compared to pre-drought conditions. We argue that CO 2 emission of climate extremes deserve more attention, because their cumulative impacts on CO 2 emissions are staggering. Most countries, including the United States, do not have a comprehensive a nationwide energy-water plan to minimize their CO 2 emissions. We argue that developing a national water-energy plan under a changing climate should be prioritized in the coming years.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.