ObjectiveTo determine if the detection of physical abuse in young children with fractures is of uniform high standard in the East Anglia Region of the UK, and whether we can identify areas for improvement in our detection of high-risk groups.DesignMulticentre retrospective 4-year study.Setting7 hospitals across the East Anglia Region of Britain (East Anglia Paediatric Physical Abuse and Fractures study).ParticipantsAge groups and fractures indicated as being at higher risk for physical abuse (all children under 12 months of age, and fractures of humerus and femur in children under 36 months of age).Outcome measuresOur criterion for physical abuse was the decision of a multiagency child protection case conference (CPCC).ResultsProbability of CPCC decision of physical abuse was highest in infants, ranging from 50% of fractures sustained in the first month of life (excluding obstetric injuries) to 10% at 12 months of age. Only 46%–86% of infants (under 12 months) with a fracture were assessed by a paediatrician for physical abuse after their fracture. Significant variation in the use of skeletal surveys and in CPCC decision of physical abuse was noted in children attending different hospitals.ConclusionsIt is a concern that significant variation between hospitals was found in the investigation and detection of physical abuse as confirmed by CPCC decisions. To minimise failure to detect true cases of physical abuse, we recommend that all high-risk children should be assessed by a paediatrician prior to discharge from the emergency department. Our proposed criteria for assessment (where we found probability of CPCC decision of physical abuse was at least 10%) are any child under the age of 12 months with any fracture, under 18 months of age with femur fracture and under 24 months with humeral shaft fracture (not supracondylar).
BackgroundThe Targon FN implant was developed in 2007 to treat intracapsular neck of femur fractures. Early results from the design centre have shown good results in terms of fracture complications. We wished to see if these results can be reproduced in an independent institution.MethodsThe records of consecutive patients, treated with this implant between 2008 and 2011 at Queen Elizabeth Hospital, were identified and collected for this study. Operations were performed by all grades of surgeons under supervision as appropriate. These patients went on to have both clinical and radiological assessment for fracture healing and function.ResultsFifty-one patients were identified with 43 patients available for final follow-up. The average age was 66 years with a minimum follow-up of 24 months. A non-union rate of 0% in the undisplaced fracture group and 1 in 12 (8%) in the displaced fracture group was observed. An avascular necrosis rate of 6% and 8% was observed for undisplaced and displaced fracture types, respectively. No significant change in premorbid to postoperative ambulation was observed and there was no wound complication.ConclusionsOur study shows similar results with those of the design centre and which are superior to those currently found in the literature for the more traditional fixation methods. It also shows that the promising results with this new implant as seen from the design institutions can be reproduced by all cadres of surgeons in non-specialist practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.