This prospective assessment of postplacental TCu380A intrauterine device placement, with ultrasound to confirm device position, finds a complete intrauterine device expulsion proportion of 8.0% at 6 months. The association of increasing parity with expulsion is consistent with prior research. The clinical significance of covariates associated with partial expulsion (provider specialty and gestational weight gain) is unclear. Due to the observational study design, any associations cannot imply causality. The proportion of partially expelled and malpositioned intrauterine devices was high, and the area under the receiver operating characteristics curve of 0.5 indicates that a string check is a poor test for assessing device position. Women considering a postplacental intrauterine device should be counseled about the risk of position abnormalities, as well as the possibility of nonvisible strings, which may complicate clinical follow-up. The clinical significance of intrauterine device position abnormalities is unknown; future research should evaluate the influence of malposition and partial expulsion on contraceptive effectiveness and side effects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.