Renal artery stenosis (RAS) is one of the main correctable causes of secondary systemic arterial hypertension. Color Doppler ultrasound (DUS), a non-invasive imaging modality, has been used to diagnose RAS in hypertensive patients. This study was conducted in the period between June 2008 and March 2010 to compare the sensitivity, specificity, accuracy and predictive values of DUS using contrast-enhanced magnetic resonance angiography (CEMRA) as the gold standard for the diagnosis of RAS. Fifty-seven consecutive patients with clinical findings suggestive of RAS (32 males and 25 females) with a mean age of 56 years (±7.92 years) were referred to the University Kebangsaan Medical Center to be screened for RAS using DUS and CEMRA. RAS was considered significant if the reduction in diameter was >60%. A total of 114 arteries were assessed, 65 in males (57%) and 49 in females (43%). On DUS, the parameters measured were the peak systolic velocity at the proximal main renal artery (PSV-P), distal main renal artery (PSV-D) and the suprarenal aorta (PSV-A) at the level of the renal hila and the acceleration time (AT) at the main renal artery. The renal-renal ratio (RRR), which is the value of PSV-P/PSV-D, and the renal-aortic ratio (RAR), which is the value of PSV-P/PSV-A, were then calculated. The accuracy, sensitivity, specificity and positive and negative predictive values of DUS in the detection of significant RAS were determined. All measured DUS parameters were positive for the detection of RAS, with an accuracy of 98.3%. On retrospective review, all the arteries that showed significant stenosis on CEMRA demonstrated an irregular outline on DUS. We conclude that DUS is accurate in the diagnosis of significant RAS but is not very sensitive as a screening tool.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.