Background: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity.Methods: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied.Results: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted.Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest.This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps.Conclusions: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.
Pregnancy poses a threat to women with aortopathy. Conclusive data on the obstetric and aortic outcome in this risk collective, especially when it comes to aortic complications in the long term, are still missing. This study offers a comparative analysis of pregnancy-associated outcome in 113 consecutive women with Marfan syndrome or bicuspid aortic valve disease, including 46 ever-pregnant and 37 never-pregnant women with Marfan syndrome, and 23 ever-pregnant and 7 never-pregnant females with bicuspid aortic valve disease. The overall obstetric outcome was comparable between ever-pregnant women with Marfan syndrome and with bicuspid aortic valve disease (p = 0.112). Pregnancy-associated aortic dissection occurred in two women with Marfan syndrome (3%) during a total of 62 completed pregnancies, whereas no single case of aortic event occurred in women with bicuspid aortic valve disease during a total of 36 completed pregnancies (p = 0.530). In the long-term follow-up, aortic dissection occurred in 21% of ever-pregnant women with Marfan syndrome, but in none of the women with bicuspid aortic valve disease (p = 0.022). Proximal aortic surgery was performed with similar frequency in ever-pregnant women with Marfan syndrome and with bicuspid aortic valve disease in the long term (p = 0.252). However, ever-pregnant women with Marfan syndrome were younger when surgery was performed (44 ± 9 vs. 59 ± 7 years; p = 0.041). In Marfan syndrome, long-term growth of the aorta was comparable between ever-pregnant and never-pregnant women. Pregnancy thus exhibited an increased immediate aortic risk only in women with Marfan syndrome, but not in women with bicuspid aortic valve disease. Previous pregnancy did not relate to an increased long-term risk of adverse aortic events in women with Marfan syndrome or with bicuspid aortic valve disease.
Robotic-assisted percutaneous coronary interventions (rPCI) have proven feasible and safe while reducing radiation exposure for the operator. Recently, rPCI systems have been refined to facilitate the treatment of complex lesions. The aim of the current study was to evaluate challenges and opportunities of establishing an rPCI program at a tertiary referral center. rPCI was performed using the CorPath GRX Vascular Robotic System (Corindus Inc., a Siemens Healthineers Company, Waltham, USA). Baseline, procedural, and in-hospital follow-up data were prospectively assessed. rPCI success was defined as completion of the PCI without or with partial manual assistance. The safety endpoint was the composite of missing angiographic success or procedure-related adverse events during hospital stay. Overall, 86 coronary lesions were treated in 71 patients (28.2% female) from January to April 2021. Median age was 71.0 years (IQR 60.3; 79.8). Indications for rPCI were stable angina pectoris (71.8%), unstable angina (12.7%) and non-ST elevation myocardial infarction (15.5%). Most lesions were complex (type B2/C: 88.4%) and included 7 cases of rPCI for chronic total occlusions. Angiographic and rPCI success were achieved in 100.0% and 94.2%, respectively. Partial manual assistance was used in 25.6%. Conversion to manual PCI was required in 5.8%. The safety endpoint occurred in 7.0% of patients. rPCI when applied as clinical routine for complex coronary lesions is effective with good immediate angiographic and clinical results. Future investigations should focus on the identification of patients that particularly benefit from robotic-assisted vs. manual PCI despite higher resource utilization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.