Reflectance anisotropy spectroscopy (RAS), which was originally invented to monitor epitaxial growth, can—as we have previously shown—also be used to monitor the reactive ion etching of III/V semiconductor samples in situ and in real time, as long as the etching rate is not too high and the abrasion at the etch front is not totally chaotic. Moreover, we have proven that—using RAS equipment and optical Fabry‒Perot oscillations due to the ever-shrinking thickness of the uppermost etched layer—the in situ etch-depth resolution can be as good as ±0.8 nm, employing a Vernier-scale type measurement and evaluation procedure. Nominally, this amounts to ±1.3 lattice constants in our exemplary material system, AlGaAsSb, on a GaAs or GaSb substrate. In this contribution, we show that resolutions of about ±5.6 nm can be reliably achieved without a Vernier scale protocol by employing thin doped layers or sharp interfaces between differently doped layers or quantum-dot (QD) layers as etch-stop indicators. These indicator layers can either be added to the device layer design on purpose or be part of it incidentally due to the functionality of the device. For typical etch rates in the range of 0.7 to 1.3 nm/s (that is, about 40 to 80 nm/min), the RAS spectrum will show a distinct change even for very thin indicator layers, which allows for the precise termination of the etch run.
The occurrence of inhomogeneous spin-density distribution in multilayered ferromagnetic diluted magnetic semiconductor nanostructures leads to strong dependence of the spin-polarized transport properties on these systems. The spin-dependent mobility, conductivity and resistivity in (Ga,Mn)As/GaAs, (Ga,Mn)N/GaN, and (Si,Mn)/Si multilayers are calculated as a function of temperature, scaled by the average magnetization of the diluted magnetic semiconductor layers. An increase of the resistivity near the transition temperature is obtained. We observed that the spinpolarized transport properties changes strongly among the three materials.
Semiconductor multilayer and device fabrication is a complex task in electronics and opto-electronics. Layer dry etching is one of the process steps to achieve a specific lateral device design. In situ and real-time monitoring of etch depth will be necessary if high precision in etch depth is required. Nondestructive optical techniques are the methods of choice. Reflectance anisotropy spectroscopy equipment has been used to monitor the accurate etch depth during reactive ion etching of III/V semiconductor samples in situ and real time. For this purpose, temporal Fabry–Perot oscillations due to the etch-related shrinking thickness of the uppermost layer have been exploited. Earlier, we have already reported an etch-depth resolution of ±16.0 nm. By the use of a quadruple-Vernier-scale measurement and an evaluation protocol, now we even improve the in situ real-time etch-depth resolution by a factor of 20, i.e., nominally down to ±0.8 nm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.