ImportanceTo our knowledge, there have been no clinical trials of ultra-high-dose-rate radiotherapy delivered at more than 40 Gy/sec, known as FLASH therapy, nor first-in-human use of proton FLASH.ObjectivesTo assess the clinical workflow feasibility and treatment-related toxic effects of FLASH and pain relief at the treatment sites.Design, Setting, and ParticipantsIn the FAST-01 nonrandomized trial, participants treated at Cincinnati Children’s/UC Health Proton Therapy Center underwent palliative FLASH radiotherapy to extremity bone metastases. Patients 18 years and older with 1 to 3 painful extremity bone metastases and life expectancies of 2 months or more were eligible. Patients were excluded if they had foot, hand, and wrist metastases; metastases locally treated in the 2 weeks prior; metal implants in the treatment field; known enhanced tissue radiosensitivity; and implanted devices at risk of malfunction with radiotherapy. One of 11 patients who consented was excluded based on eligibility. The end points were evaluated at 3 months posttreatment, and patients were followed up through death or loss to follow-up for toxic effects and pain assessments. Of the 10 included patients, 2 died after the 2-month follow-up but before the 3-month follow-up; 8 participants completed the 3-month evaluation. Data were collected from November 3, 2020, to January 28, 2022, and analyzed from January 28, 2022, to September 1, 2022.InterventionsBone metastases were treated on a FLASH-enabled (≥40 Gy/sec) proton radiotherapy system using a single-transmission proton beam. This is consistent with standard of care using the same prescription (8 Gy in a single fraction) but on a conventional-dose-rate (approximately 0.03 Gy/sec) photon radiotherapy system.Main Outcome and MeasuresMain outcomes included patient time on the treatment couch, device-related treatment delays, adverse events related to FLASH, patient-reported pain scores, and analgesic use.ResultsA total of 10 patients (age range, 27-81 years [median age, 63 years]; 5 [50%] male) underwent FLASH radiotherapy at 12 metastatic sites. There were no FLASH-related technical issues or delays. The average (range) time on the treatment couch was 18.9 (11-33) minutes per patient and 15.8 (11-22) minutes per treatment site. Median (range) follow-up was 4.8 (2.3-13.0) months. Adverse events were mild and consistent with conventional radiotherapy. Transient pain flares occurred in 4 of the 12 treated sites (33%). In 8 of the 12 sites (67%) patients reported pain relief, and in 6 of the 12 sites (50%) patients reported a complete response (no pain).Conclusions and RelevanceIn this nonrandomized trial, clinical workflow metrics, treatment efficacy, and safety data demonstrated that ultra-high-dose-rate proton FLASH radiotherapy was clinically feasible. The treatment efficacy and the profile of adverse events were comparable with those of standard-of-care radiotherapy. These findings support the further exploration of FLASH radiotherapy in patients with cancer.Trial RegistrationClinicalTrials.gov Identifier: NCT04592887
PurposeThe study assessed the outcomes of patients at a single institution with locally advanced primary and recurrent pelvic malignancies treated with interstitial high-dose-rate (HDR) or low-dose-rate (LDR) brachytherapy (BT), using a modified Syed-Neblett template.Material and methodsBetween 1996 and 2010, 60 patients with primary or recurrent pelvic malignancies were treated with interstitial BT. Thirty three patients had primary malignancies with 6.1% being stage I, 33.3% stage II, 45.5% stage III, and 15.2% stage IV; the remaining 27 patients were recurrent malignancies. Fifty four patients received external beam radiotherapy (EBRT) as part of their treatment course. The median EBRT, BT, and EBRT + BT doses were 45 Gy, 20 Gy, and 65 Gy, respectively. Thirty eight patients received concurrent chemotherapy with EBRT. Complete response (CR) was defined by absence of clinical and radiographic disease on first follow-up. Toxicity was graded as per Common Terminology Criteria for Adverse Events, version 4.0.ResultsThe median follow-up was 37 months (4-234 months) and initial CR was achieved in 91%. For primary cancers at diagnosis, 5-year local control (LC), 5-year progression-free survival (PFS), 5-year overall survival (OS) were 65%, 64%, and 42% respectively. For recurrent cancers at diagnosis, 5-year LC, 5-year PFS, and 5-year OS were 80%, 51%, and 37%, respectively. There was a significant difference in both OS and PFS among different tumor sites (p < 0.05), with vaginal cancers having the best 5-year OS (55%) and PFS (84%). There was a total of 1 acute toxicity ≥ grade 3, 6 late grade 3 toxicities, and late grade 4 toxicity.ConclusionsOur series suggests that interstitial BT using a modified Syed-Neblett template is a safe and effective treatment for primary or recurrent pelvic malignancies. This technique allowed effective LC and 97% of patients had preservation of both bladder and rectal function.
Background In preclinical studies, FLASH therapy, in which radiation delivered at ultrahigh dose rates of ≥40 Gy per second, has been shown to cause less injury to normal tissues than radiotherapy delivered at conventional dose rates. This paper describes the protocol for the first-in-human clinical investigation of proton FLASH therapy. Objective FAST-01 is a prospective, single-center trial designed to assess the workflow feasibility, toxicity, and efficacy of FLASH therapy for the treatment of painful bone metastases in the extremities. Methods Following informed consent, 10 subjects aged ≥18 years with up to 3 painful bone metastases in the extremities (excluding the feet, hands, and wrists) will be enrolled. A treatment field selected from a predefined library of plans with fixed field sizes (from 7.5 cm × 7.5 cm up to 7.5 cm × 20 cm) will be used for treatment. Subjects will receive 8 Gy of radiation in a single fraction—a well-established palliative regimen evaluated in prior investigations using conventional dose rate photon radiotherapy. A FLASH-enabled Varian ProBeam proton therapy unit will be used to deliver treatment to the target volume at a dose rate of ≥40 Gy per second, using the plateau (transmission) portion of the proton beam. After treatment, subjects will be assessed for pain response as well as any adverse effects of FLASH radiation. The primary end points include assessing the workflow feasibility and toxicity of FLASH treatment. The secondary end point is pain response at the treated site(s), as measured by patient-reported pain scores, the use of pain medication, and any flare in bone pain after treatment. The results will be compared to those reported historically for conventional dose rate photon radiotherapy, using the same radiation dose and fractionation. Results FAST-01 opened to enrollment on November 3, 2020. Initial results are expected to be published in 2022. Conclusions The results of this investigation will contribute to further developing and optimizing the FLASH-enabled ProBeam proton therapy system workflow. The pain response and toxicity data acquired in our study will provide a greater understanding of FLASH treatment effects on tumor responses and normal tissue toxicities, and they will inform future FLASH trial designs. Trial Registration : ClinicalTrials.gov NCT04592887; http://clinicaltrials.gov/ct2/show/NCT04592887 International Registered Report Identifier (IRRID) DERR1-10.2196/41812
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.