Purpose: Permanent interstitial brachytherapy is an appealing treatment modality for patients with locoregional recurrent, resectable head and neck carcinoma (HNC), having previously received radiation. Cesium-131 (131 Cs) is a permanent implant brachytherapy isotope, with a low average photon energy of 30 keV and a short half-life of 9.7 days. Exposure to medical staff and family members is low; patient isolation and patient room shielding are not required. This work presents a single institution's implementation process of utilizing an intraoperative, permanent 131 Cs implant for patients with completely resected recurrent HNC. Material and methods: Fifteen patients receiving 131 Cs permanent seed brachytherapy were included in this analysis. The process of pre-planning, selecting the dose prescription, seed ordering, intraoperative procedures, post-implant planning, and radiation safety protocols are described. Results: Tumor volumes were contoured on the available preoperative PET/CT scans and a pre-implant treatment plan was created using uniform source strength and uniform 1 cm seed spacing. Implants were performed intraoperatively, following tumor resection. In five of the fifteen cases, intraoperative findings necessitated a change from the planned number of seeds and recalculation of the pre-implant plan. The average prescription dose was 56.1 ±6.6 Gy (range, 40-60 Gy). The average seed strength used was 2.2 ±0.2 U (3.5 ±0.3 mCi). Patients returned to a recovery room on a standard surgical floor and remained inpatients, without radiation safety restrictions, based on standard surgical recovery protocols. A post-implant treatment plan was generated based on immediate post-operative CT imaging to verify the seed distribution and confirm delivery of the prescription dose. Patients were provided educational information regarding radiation safety recommendations. Conclusions: Cesium-131 interstitial brachytherapy is feasible and does not pose major radiation safety concerns; it should be considered as a treatment option for previously irradiated patients with recurrent, resectable HNC.
Background This study investigates daily breast geometry and delivered dose to prone-positioned patients undergoing tangential whole breast radiation therapy (WBRT) on an O-ring linear accelerator with 6X flattening filter free mode (6X-FFF), planned with electronic compensation (ECOMP) method. Most practices rely on skin marks or daily planar image matching for prone breast WBRT. This system provides low dose daily CBCT, which was used to study daily robustness of delivered dose parameters for prone-positioned WBRT. Methods Eight patients treated with 16-fraction prone-breast WBRT were retrospectively studied. Planning CTs were deformed to daily CBCT to generate daily synthetic CTs, on which delivered dose distributions were calculated. A total of 8 × 16 = 128 synthetic CTs were generated. Consensus ASTRO definition was used to contour Breast PTV Eval for each daily deformed CT. Breast PTV Eval coverage (V90%) and hotspot (V105% and Dmax) were monitored daily to compare prescription dose with daily delivered dose. Various predictors including patient weight, breast width diameter (BWD), and Dice similarity coefficient (DSC) were fit into an analysis of covariance model predicting V90% and V105% deviation from prescribed (ΔV90%, ΔV105%). Statistical significance is indicated with asterisks (* for p < 0.05; ** for p < 0.001). Results Daily delivered Breast PTV Eval V90% was moderately smaller than prescribed (median ΔV90% = − 0.1%*), while V105% was much larger (median ΔV105% = + 10.1%** or + 92.4 cc**). Patient’s weight loss correlated with significantly increased ΔV105% (+ 4.6%/ − 1% weight, R2 = 0.4**) and moderately decreased ΔV90% (− 0.071%/ − 1% wt., R2 = 0.2**). Comprehensive ANCOVA models indicated three factors affect ΔV90% and ΔV105% the most: (1) BWD decrease (− 0.09%* and + 10%**/ − 1 cm respectively), (2) PTV Eval volume decrease (− 0.4%** and + 9%**/ − 100 cc), and for ΔV105% only, (3) the extent of breast deformation (+ 10%**/ − 0.01 DSC). Breast PTV Eval volume also decreased with time (− 2.21*cc/fx), possibly indicating seroma resolution and increase in V105% over time. Conclusions Daily CBCT revealed key delivered dose parameters vary significantly for patients undergoing tangential prone breast WBRT planned with ECOMP using 6X-FFF. Patient weight, BWD, and breast shape deformation could be used to predict dosimetric variations from prescribed. Preliminary findings suggest an adaptive plan based on daily CBCT could reduce excessive dose to the breast.
PurposeIntraoperatively implanted Cesium-131 (131Cs) permanent seed brachytherapy is used to deliver highly localized re-irradiation in recurrent head and neck cancers. A single planar implant of uniform air kerma strength (AKS) seeds and 10 mm seed-to-seed spacing is used to deliver the prescribed dose to a point 5 mm or 10 mm perpendicular to the center of the implant plane. Nomogram tables to quickly determine the required AKS for rectangular and irregularly shaped implants were created and dosimetrically verified. By eliminating the need for a full treatment planning system plan, nomogram tables allow for fast dose calculation for intraoperative re-planning and for a second check method.Material and methodsTG-43U1 recommended parameters were used to create a point-source model in MATLAB. The dose delivered to the prescription point from a single 1 U seed at each possible location in the implant plane was calculated. Implant tables were verified using an independent seed model in MIM Symphony LDR™. Implant tables were used to retrospectively determine seed AKS for previous cases: three rectangular and three irregular.ResultsFor rectangular implants, the percent difference between required seed AKS calculated using MATLAB and MIM was at most 0.6%. For irregular implants, the percent difference between MATLAB and MIM calculations for individual seed locations was within 1.5% with outliers of less than 3.1% at two distal locations (10.6 cm and 8.8 cm), which have minimal dose contribution to the prescription point. The retrospectively determined AKS for patient implants using nomogram tables agreed with previous calculations within 5% for all six cases.ConclusionsNomogram tables were created to determine required AKS per seed for planar uniform AKS 131Cs implants. Comparison with the treatment planning system confirms dosimetric accuracy that is acceptable for use as a second check or for dose calculation in cases of intraoperative re-planning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.