Orthopaedic surgery's slow increase in the number of female residents and academic faculty lags behind that of other specialties. The lack of female orthopaedic surgeons in higher ranks within medical schools is detrimental to recruitment of female medical students to the field. Further efforts should be made toward increasing medical student exposure to orthopaedics and to female mentors in an effort to ensure that the field continues to attract the nation's top medical graduates.
This animal study presents data suggesting that the use of intra-articular vancomycin powder for reducing the risk of periprosthetic joint infections should be investigated further in clinical studies.
Hip arthroscopy has become the standard treatment for symptomatic femoroacetabular impingement as patients have shown good outcomes and high satisfaction with this intervention. However, capsular management to gain access for intra-articular procedures remains greatly debated. Capsular closure is advocated particularly in the setting of interportal or T-capsulotomy to avoid complications of instability or nonhealing capsule. We introduce a technique for capsular management through a limited periportal capsulotomy during arthroscopic treatment of femoroacetabular impingement. In using dilation of the anterolateral and mid-anterior portals without completion of a full interportal capsulotomy, the stabilizing iliofemoral ligament is preserved. We have found that periportal capsulotomy provides safe and sufficient access to the hip joint without necessitating capsular closure.
Background:Attritional bone loss in patients with recurrent anterior instability has successfully been treated with a bone block procedure such as the Latarjet. It has not been previously demonstrated whether cortical or cancellous screws are superior when used for this procedure.Purpose:To assess the strength of stainless steel cortical screws versus stainless steel cannulated cancellous screws in the Latarjet procedure.Study Design:Controlled laboratory study.Methods:Ten fresh-frozen matched-pair shoulder specimens were randomized into 2 separate fixation groups: (1) 3.5-mm stainless steel cortical screws and (2) 4.0-mm stainless steel partially threaded cannulated cancellous screws. Shoulder specimens were dissected free of all soft tissue and a 25% glenoid defect was created. The coracoid process was osteomized, placed at the site of the glenoid defect, and fixed in place with 2 parallel screws.Results:All 10 specimens failed by screw cutout. Nine of 10 specimens failed by progressive displacement with an increased number of cycles. One specimen in the 4.0-mm screw group failed by catastrophic failure on initiation of the testing protocol. The 3.5-mm screws had a mean of 274 cycles (SD, ±171 cycles; range, 10-443 cycles) to failure. The 4.0-mm screws had a mean of 135 cycles (SD, ±141 cycles; range, 0-284 cycles) to failure. There was no statistically significant difference between the 2 types of screws for cycles required to cause failure (P = .144).Conclusion:There was no statistically significant difference in energy or cycles to failure when comparing the stainless steel cortical screws versus partially threaded cannulated cancellous screws.Clinical Relevance:Latarjet may be performed using cortical or cancellous screws without a clear advantage of either option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.