Purpose. To evaluate the corneal endothelial cell density and morphology in normal Egyptian eyes. Methods. In total, 568 healthy eyes of 568 Egyptian volunteers aged 20 to 85 years were examined using noncontact specular microscopy for the central corneal thickness (CCT), mean endothelial cell density (MCD), coefficient of variation (CV) in cell area, mean cell area (MCA), and hexagonal cell (Hex) percentage. Variables were compared between sexes and between different age groups. Results. The mean CCT, MCD, and MCA were 514.45 ± 43.04 μm, 2647.50 ± 382.62 cells/mm2, and 390.59 ± 149.94 μm2, respectively. MCD and MCA showed no significant differences between men and women (P=0.171 and 0.099, respectively), whereas CV (%) and Hex (%) showed significant differences (P=0.024 and 0.015, respectively). CCT (P=0.007, r = −0.113) and MCD (P<0.001, r = −0.357) exhibited a significant negative correlation with age, whereas CV (%) (P<0.001, r = 0.341) and MCA (P=0.008, r = 0.111) exhibited a significant positive correlation. The mean rate of endothelial cell loss from 20 to 85 years of age was 0.3% per year. Conclusions. Our results provide normative data for the corneal endothelium in healthy Egyptian eyes, thus increasing the knowledge base for corneal endothelial cell parameters in healthy Egyptian eyes. Furthermore, our findings can be used as baseline values for comparisons between Egyptian and other populations and for studies of the endothelial cell reserve and capacity for intraocular surgery and corneal transplantation.
Purpose. To examine the morphological changes in the meibomian glands of patients with keratoconus as well as to study the relationship between these changes in the morphology and several tear film parameters. Methods. Examination of the meibomian gland (MG) of 300 keratoconus patients presenting to the center using infrared noncontact meibography system (Sirius, CSO, Italy) between January 2017—January 2019. 100 eyes of healthy individuals were also enrolled as a control group. Tear breakup time (TBUT) test and Schirmer test II were evaluated. Subjective symptoms were also assessed using Ocular Surface Disease Index (OSDI). Results. Mean age of keratoconus patients was 19 ± 12 years and 21 ± 14 years in control group. Average TBUT was 4.9 ± 2.1 sec. and average Schirmer test was 5.3 ± 2.2 mm which was significantly lower than control group (p=0.05). Meibomian gland dropout in the lower eyelid of the keratoconus group was as follows: grade 0 (no loss of meibomian glands): 100 eyes; grade 1 (gland dropout area <1/3 of the total meibomian glands): 85 eyes; grade 2 (gland dropout area 1/3 to 2/3): 68 eyes; and grade 3 (gland dropout >2/3): 47 eyes. Conclusion. Keratoconus shows significant meibomian gland dropout and distortion that can be recorded by noncontact meibography. Sirius meibography is a simple, cost-effective method of evaluating meibomian gland dropout as a part of the routine refractive examination.
ObjectivesTo document the difference between complication rate in the early curve of practicing intracorneal stromal rings and after gaining experience.Patients and methodsA retrospective study of 623 eyes of 417 patients with keratoconus who underwent Keraring implantation using femtosecond laser for channel creation.ResultsThe main outcome measures were reported intraoperative and postoperative complications. The overall complication rate was 12.7% (79 eyes) over the 4 years with 34 eyes in the first year (5.5%) and six eyes in the fourth year (0.96%). Over the 4 years of our practice, intraoperative complications were 7.1% and postoperative complications were 5.6%. Yet, there was a significant difference in intraoperative complications between the first and the fourth year where it was 3.5% and 0.48%, respectively. This also applies to the postoperative complication rate, which decreased from 1.9% to 0.5% in the fourth year.ConclusionComplications with femtosecond-assisted intracorneal stromal ring procedure can be reduced by experience, making this procedure a safe and effective means of treating keratoconus. Yet, there are some complications that cannot be avoided such as sterile keratitis.
Purpose. To study the relation between the serum 25-hydroxyl vitamin D (OH D) level and the occurrence of age-related cataract in a case-control study. Patients and Methods. 325 cataract patients and 385 control individuals of both sexes were examined for the 25-OH D level using the chemiluminescent microparticle immunoassay (CMIA) technology. Results. Mean 25-OH D level in cataract patients was 7.6 ± 5.5 ± 11.2 ng/mL and median was 5.6 (2.6–31.9), while in the control group, mean 25-OH D level was 18.5 ± 9.6 ng/mL and median was 17.8 (3.4–37.8) (p value < 0.001). There was a statistically significant difference among the different types of cataracts with the lowest level in nuclear cataract. Conclusion. 25-OH D levels in all enrolled individuals were below the reference levels with a severe deficiency in cataract patients. These results might highlight the role of deficiency of 25-OH D in age-related cataract patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.