The high rates of both acute hemostasis and recurrent bleeding suggest that Hemospray may be used in high-risk cases as a temporary measure or a bridge toward more definitive therapy.
Our results revealed a 41% positive yield from brushing cytology. The sensitivity of biliary brushing cytology in our center was 61% and the specificity was 98%. Predictors of positive yield include older age, mass size>1 cm, and stricture length of >1 cm.
Background and aims: The ability to safely and effectively obtain sufficient tissue for pathologic evaluation by using endoscopic ultrasound (EUS) guidance remains a challenge. Novel designs in EUS needles may provide for improved ability to obtain such core biopsies. The aim of this study was to evaluate the diagnostic yield of core biopsy specimens obtained using a novel EUS needle specifically designed to obtain core biopsies.
Patients and methods: Multicenter retrospective review of all EUS-guided fine-needle biopsies obtained using a novel biopsy needle (SharkCore FNB needle, Medtronic, Dublin, Ireland). Data regarding patient demographics, lesion type/location, technical parameters, and diagnostic yield was obtained.
Results: A total of 250 lesions were biopsied in 226 patients (Median age 66 years; 113 (50 %) male). Median size of all lesions (mm): 26 (2 – 150). Overall, a cytologic diagnosis was rendered in 81 % specimens with a median number of 3 passes. When rapid onsite cytologic evaluation (ROSE) was used, cytologic diagnostic yield was 126/149 (85 %) with a median number of 3 passes; without ROSE, cytologic diagnostic yield was 31/45 (69 %, P = 0.03) with a median number of 3 passes. Overall, a pathologic diagnosis was rendered in 130/147 (88 %) specimens with a median number of 2 passes. Pathologic diagnostic yield for specific lesion types: pancreas 70/81 (86 %), subepithelial lesion 13/15 (87 %), lymph node 26/28 (93 %). Ten patients (10/226, 4 %) experienced adverse events: 4 acute pancreatitis, 5 pain, 1 fever/cholangitis.
Conclusions: Initial experience with a novel EUS core biopsy needle demonstrates excellent pathologic diagnostic yield with a minimum number of passes.
(i) Bilateral CPB/N is more effective than central CPB/N; (ii) bilateral CPB/N is safe, but on rare occasions can cause trauma to the left adrenal artery; it should therefore be avoided in patients with a bleeding diathesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.