Using a high-efficiency grating interferometer for hard X rays (10-30 keV) and a phase-stepping technique, separate radiographs of the phase and absorption profiles of bulk samples can be obtained from a single set of measurements. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index, with a spatial resolution down to a few microns. The method is mechanically robust, requires little spatial coherence and monochromaticity, and can be scaled up to large fields of view, with a detector of correspondingly moderate spatial resolution. These are important prerequisites for use with laboratory X-ray sources.
An x-ray interferometer has been developed that uses two transmission phase gratings to analyze wave front distortions in the hard x-ray range. The interferometer is insensitive to mechanical drift and vibrations, and it is tunable over a wide range of photon energies. This setup was used for differential phase contrast imaging of low-absorbing test objects. We obtained micrographs with moiré fringes of good visibility, which revealed the local phase shift gradient caused by the objects. A comparison with numerically simulated images indicates that quantitative analysis of unknown phase objects is possible.
We present a new method to analyze quantitatively the wave front of a partially coherent x-ray beam. The technique is based on the use of two-dimensional speckle patterns combined with digital image correlation algorithms and offers a pixel size resolution, a high accuracy, and a reduced sensitivity to mechanical vibrations thanks to a very simple setup. The requirements on transverse and longitudinal coherence are also low. Finally, we show how the method can be used for phase contrast imaging applications by a single sample exposure process.
Hard x-ray absorption spectroscopy is combined with scanning microtomography to reconstruct full near-edge spectra of an elemental species at each location on an arbitrary virtual section through a sample. These spectra reveal the local concentrations of different chemical compounds of the absorbing element inside the sample and give insight into the oxidation state, the local atomic structure, and the local projected free density of states. The method is implemented by combining a quick scanning monochromator and data acquisition system with a scanning microprobe setup based on refractive x-ray lenses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.