Photolysis of fluoren-9-01 (1) in aqueous methanol solution results in efficient formation of 9-methoxyfluorene (2); the driving force for the photosolvolysis is believed to be the formation of an aromatic 4n cationic system in the excited-state.
We report the development and application of a capillary hollow fibre membrane interface using methanol as an acceptor phase to deliver target analytes to an electrospray ionization source and a triple quadrupole mass spectrometer. Superior fluid handling systems lead to greater signal stability and membrane integrity for the continuous on-line monitoring of polar and charged analytes in complex aqueous samples with detection limits in the parts-per-trillion to parts-per-billion range. The system can be operated in either a continuous flow or a stopped acceptor flow mode - the latter giving rise to greater sensitivity. We report detection limits, enrichment factors and signal response times for selected analytes with polydimethylsiloxane and Nafion® polymer membrane interfaces. In addition, we demonstrate the use of this interface to detect pharmaceuticals and other contaminants in natural water and artificial urine. The improved sensitivity and analytical response times of our CP-MIMS system make it possible to continuously monitor dynamic chemical systems with temporal resolutions on the order of minutes. Presented is a comparison of the performance of CP-MIMS versus direct infusion electrospray ionization, demonstrating the potential advantages over direct infusion for trace analyte measurements in complex, high ionic strength samples. Furthermore, by continuously flowing a reaction mixture in a closed loop over the interface, we demonstrate the use of the system as an in situ reaction-monitoring platform for the chlorination of a model organic compound in aqueous solution.
Delicate PDMS HFM CP-MIMS interfaces were developed and used for the direct, on-line detection of low volatility, polar analytes in complex aqueous samples. Composite PDMS HFM interfaces yielded the best overall analytical performance improvements, and were used to demonstrate the direct measurement of naphthenic acids in complex aqueous samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.