We report contemporary structural models and staffing practices in a sample of US ICUs caring for critically ill cardiovascular patients. Although most hospitals surveyed had dedicated CICUs, a minority of CICUs employed a 'closed' CICU model and few had routine intensivist staffing. Most CICU directors agree that there is a need for cardiologists with intensivist training and expertise. These survey data reveal potential areas for continued improvement in US CICU organizational structure and physician staffing.
Background: High-sensitivity cardiac troponin T (hsTnT) is used in many countries, but is not available in the United States. Prior evidence has been viewed as inconclusive as to whether low cardiac troponin T (cTnT) concentrations detected with hsTnT are prognostically meaningful compared with fourth-generation cTnT. Hypothesis: The aim of this study was to assess the prognostic performance of low-level cTnT elevations using the hsTnT assay compared with the assay (fourth-generation) currently available in the United States. Methods: We measured serum cTnT in 4160 patients with non-ST-elevation acute coronary syndrome using both the hsTnT and fourth-generation assays. Patients were stratified at the 99th percentile cut point for each assay.Results: Patients with baseline hsTnT ≥14 ng/L (n = 3697) vs <14 ng/L were at higher 30-day risk of cardiovascular death (CVD) or myocardial infarction (MI) (9.1% vs 1.9%, P < 0.0001). After adjusting for all other elements of the Thrombolysis In Myocardial Infarction risk score, hsTnT ≥14 carried a 5.2-fold higher risk of CVD/MI (95% confidence interval [CI]: 2.6-10.1, P < 0.0001). Low levels of hsTnT (14-50 ng/L) also revealed increased risk (CVD/MI: 6.4%, P = 0.002). Importantly, patients with negative fourth-generation cTnT but positive hsTnT were at 4.5-times higher risk of CVD/MI (95% CI: 1.9-11.0, P = 0.0008) than patients with negative hsTnT. In contrast, patients with a negative hsTnT but positive fourth-generation cTnT result had a lower rate of CVD/MI than with a positive hsTnT (1.3% vs 8.2%, P = 0.0005). Conclusions: Low-level increases in cTnT detected using the hsTnT assay identified patients at a meaningfully higher risk and who might otherwise be missed, and improves upon risk stratification using the cTnT assay currently available in the United States.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.