OBJECTIVE: To investigate the reliability of the 50-Foot Walk Test (50 FWT) and 30-second Chair Stand Test (30 CST) in patients who have undergone total knee arthroplasty (TKA). METHODS: The study was designed as a test-retest research. Thirty-three patients who would undergo bilateral TKA were recruited. The tests 30 CST and 50 FWT were performed twice on the same day with 5-minute intervals, respectively. Between the first and second tests, patients waited for an hour on sitting position in order to prevent fatigue. In addition to these tests, we registered the knee pain experienced by the patients using a 100 mm VAS scale. RESULTS: The 50 FWT and 30 CST showed excellent reliability. ICC for 50 FWT and 30 CST were 0.97 and 0.92, respectively. SRD95 was 1.07 for 50 FWT and 0.96 for 30 CST. CONCLUSIONS: According to results of this study, both 50 FWT and 30 CST have excellent reliability in patients with TKA. These tests are simple, no time consuming and constitute sensitive methods to measure the functional performance in patients with TKA in the clinical settings. Clinicians and researchers may use these tests to quantify even small changes in functional performance for patients with TKA. Level of Evidence III, Diagnostic Study.
Both the 4 MWT and the 10 MWT have excellent reliability in patients undergoing lower extremity surgery such as TKA, THA, LEF and soft tissue operation during inpatient rehabilitation. Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status, represent a real clinical change in rehabilitation process. Implications for Rehabilitation The 4 MWT and the 10 MWT are simple methods and were also shown to be reliable measurement methods in many patient groups. This study illustrates that the test-retest reliability of the 4 MWT and 10 MWT are excellent in patients undergoing lower extremity surgery during inpatient rehabilitation (ICC: 0.94 for 4 MWT, ICC: 0.95 for 10 MWT). Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status represent a real clinical change in rehabilitation process.
Background:
Evaluation of range of motion (ROM) is integral to assessment of the musculoskeletal system, is required in health fitness and pathologic conditions, and is used as an objective outcome measure. Several methods are described to check ROM, each with advantages and disadvantages. Hence, this study introduces a new device using a smartphone goniometer to measure ankle joint ROM.
Objective:
To test the reliability of smartphone goniometry in the ankle joint by comparing it with the universal goniometer (UG) and to assess interrater and intrarater reliability for the smartphone goniometer record (SGR) application.
Methods:
Fifty-eight healthy volunteers (29 men and 29 women aged 18–30 years) underwent SGR and UG measurement of ankle joint dorsiflexion and plantarflexion. Two examiners measured ankle joint ROM. Descriptive statistics were calculated for descriptive and anthropometric variables, as were intraclass correlation coefficients (ICCs).
Results:
There were 58 usable data sets. For measuring ankle dorsiflexion ROM, both instruments showed excellent interrater reliability: UG (ICC = 0.87) and SGR (ICC = 0.89). Intrarater reliability was excellent in both instruments in ankle dorsiflexion: UG and SGR (mean ICC = 0.91). For measuring ankle plantarflexion, both instruments showed excellent interrater reliability: UG (ICC = 0.76) and SGR (ICC = 0.82). Intrarater reliability was excellent in both instruments in ankle plantarflexion: UG (mean ICC = 0.85) and SGR (mean ICC = 0.82).
Conclusions:
Smartphone-based goniometers can be used to assess active ROM of the ankle joint because they can achieve a high degree of intrarater and interrater reliability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.