Background-Conducting channels are the target for ventricular tachycardia (VT) ablation. Conducting channels could be identified with contrast enhanced-cardiac magnetic resonance (ce-CMR) as border zone (BZ) corridors. A 3-dimensional (3D) reconstruction of the ce-CMR could allow visualization of the 3D structure of these BZ channels. Methods and Results-We included 21 patients with healed myocardial infarction and VT. A 3D high-resolution 3T ce-CMR was performed before CARTO-guided VT ablation. The left ventricular wall was segmented and characterized using a pixel signal intensity algorithm at 5 layers (endocardium, 25%, 50%, 75%, epicardium). A 3D color-coded shell map was obtained for each layer to depict the scar core and BZ distribution. The presence/characteristics of BZ channels were registered for each layer. Scar area decreased progressively from endocardium to epicardium (scar area/left ventricular area: 34.0±17.4% at endocardium, 24.1±14.7% at 25%, 16.3±12.1% at 50%, 13.1±10.4 at 75%, 12.1±9.3% at epicardium; P<0.01). Forty-five BZ channels (2.1±1.0 per patient, 23.7±12.0 mm length, mean minimum width 2.5±1.5 mm) were identified, 85% between the endocardium and 50% shell and 76% present in ≥1 layer. The ce-CMR-defined BZ channels identified 74% of the critical isthmus of clinical VTs and 50% of all the conducting channels identified in electroanatomic maps. Conclusions-Scar area in patients with healed myocardial infarction decreases from the endocardium to the epicardium.BZ channels, more commonly seen in the endocardium, display a 3D structure within the myocardial wall that can be depicted with ce-CMR. The use of ce-CMR-derived maps to guide VT ablation warrants further investigation.
This paper presents a new registration algorithm, called Temporal Diffeomorphic Free Form Deformation (TDFFD), and its application to motion and strain quantification from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity field as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement field is then recovered through forward Eulerian integration of the non-stationary velocity field. The strain tensor is computed locally using the spatial derivatives of the reconstructed displacement field. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared differences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the incompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both on displacement and velocity fields, on a set of synthetic 3D US images with different noise levels. TDFFD showed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD was applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the improvement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quantified by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.