High-energy x-rays produced by radiotherapy accelerators operating at potentials above 10 MV may activate the air via (γ, n) reactions with both oxygen and nitrogen. While the activation products are relatively short-lived, personnel entering the accelerator room may inhale some radioactive air, which warrants internal dosimetry assessments. This work illustrates a method based on the use of ammonium nitrate solutions for the evaluation of photon-induced air activation and for the estimate of internal doses to radiotherapy personnel. Air activation and internal dosimetry assessments based on our method are presented for some widespread radiotherapy linear accelerator models. Our results indicate that the equivalent dose to the lungs of radiotherapy personnel is negligible for beam energies below 18 MeV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.