Ethylene concentrations were determined in gas samples extracted from sealed holes made in the sapwood and heartwood of stems of 70-100-year-old Scots pine (Pinus sylvestris L). Gas could be collected from the heartwood holes by lowering the pressure by means of a large syringe. However, attempts to extract gas from air spaces in the sapwood with the same technique failed, presumably because of lack of an interconnected system of gas-filled canals. High ethylene concentrations, usually in excess of 1 ppm, accumulated in the sapwood holes within one day after sealing. Ethylene concentrations in the sapwood rose to 3-7 ppm during the growing season, and decreased to 0.1-0.3 ppm during the winter. In response to extreme drought, sapwood ethylene concentration increased to 30 ppm, followed by a rapid decrease after the onset of rain. Ethylene concentrations in gas samples from the heartwood were consistently lower than 1 ppm. The lowest values, about 0.1 ppm, were found during the autumn and early winter, whereas values around 0.5 ppm were typical from February to August.
Background: The distal radius fracture (DRF) is the most common fracture in adults. For unstable intra-articular fractures, the choice of treatment is often operative. The optimal choice of fixation remains a matter of discussion. Question/Purpose: Can combined volar and dorsal plating, using a dorsal frame plate, achieve a good functional and radiographic 1-year outcome in intra-articular DRFs? Methods: In a retrospective cohort study, we evaluated 74 consecutive patients operated with combined plating using a volar plate and a dorsal frame plate. The DRFs were operated between 2016 and 2017 and all cases were AO type C intra-articular fractures. The primary outcome was patient-reported outcome measures including radiographic examination 1 year postoperatively. Secondary outcome measures included wrist range of motion, visual analog scale (VAS) pain scores, and hand grip strength. Results: The median patient-rated wrist evaluation score was 18 points; the quick disabilities of the arm, shoulder, and hand score was 14.8 points. The median Batra radiographic score was 88. Wrist extension was 76% of the uninjured side, flexion was 74%, pronation was 94%, and supination was 94%. VAS pain scores were 0 at rest and 2 during activity. Hand grip strength was 82% compared with the uninjured side. The radiographic outcome according to Batra did not correspond to the patient-reported outcome. Patients older than 60 years had significantly better QuickDASH (quick disabilities of the arm, shoulder, and hand) and PRWE scores (patient-rated wrist evaluation scores) and less pain during activity compared with younger patients despite similar radiographic outcome. There were no tendon ruptures; hardware removal was performed in 21 of the 74 patients. Conclusion: The radiographic outcome did not correspond to the functional outcome 1 year postoperatively. Older patients report less pain and better functional outcome compared with younger patients. There were no tendon ruptures and the frequency of hardware removal was acceptable. Complex intra-articular DRFs AO type C can be managed with volar and dorsal frame-plate fixation to restore distal radius anatomy and achieve a good functional outcome.
Background: Volar locking plate fixation is the most common method of operative fixation of distal radius fractures (DRFs). For more complex cases, combined plating is an option for stabilizing intra-articular fragments. The prevalence of posttraumatic arthritis (PA) after an intra-articular DRF, and its relation to patient-reported outcome measures (PROMs), remains unclear. The purpose of this study was to study the prevalence of PA and its correlation to clinical outcome measures. Methods: We evaluated 97 consecutive patients with intra-articular DRF, operated with combined plating, 7 years postoperatively. The primary outcome measure was the prevalence of radiographic PA. Secondary outcome measures included visual analog scale (VAS) pain score, hand grip strength, wrist range of motion (ROM), Patient-Rated Wrist Evaluation (PRWE) score, and Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score. Radiographic examination was performed between 1 and 7 years postoperatively. Results: The prevalence of PA was 29% at the 7-year follow-up. No correlation was found between PA and ROM, hand grip strength, PRWE, QuickDASH, VAS pain scores, or radiographic reduction. Median wrist ROM and grip strength were significantly inferior compared with the uninjured side. Hardware removal was performed in 51.5% of cases. There were 2 cases of tendon ruptures. Conclusions: Combined plating can yield a good clinical outcome 7 years postoperatively and a low prevalence of PA. The presence of PA did not correlate to clinical outcome measures or to the accuracy of anatomical reduction 1 year postoperatively. The frequency of tendon ruptures was acceptable, but the high frequency of hardware removal is a concern.
Background Distal radius fracture (DRF) is the most common type of fracture in children. There is no clear consensus on primary treatment for complete DRFs. Kirschner wire (K-wire) fixation has been recommended, to avoid the risk of redislocation. However, recent studies have indicated that casting can be sufficient, at least for children with two or more years left to grow. There is no recent study regarding pediatric DRFs and the extent of K-wire fixations in the Swedish population. The purpose of this study was to investigate epidemiology and treatment of pediatric DRFs registered in the Swedish Fracture Register (SFR). Methods In this retrospective study, based on data from SFR for children aged 5–12 years with DRF between January 2015 and October 2022, we investigated epidemiology and choice of treatment. Sex, age, type of DRF, treatment, cause and mechanism of injury, were analyzed. Results In total, 25,777 patients were included, 7,173 (27%) with complete fractures. Number and peak age of girls vs. boys with fractures were 11,742 (46%), 10 years, and 14,035 (54%), 12 years, respectively. Odds ratio (OR) for a K-wire fixation in girls vs. boys was 0.81 (95% confidence interval (CI) 0.74–0.89, p < .001). With age 5 -7 years as reference, OR for age group 8–10 years was 0.88 (95% CI 0.80–0.98 p = .019) and OR for age group 11–12 years was 0.81 (95% CI 0.73–0.91 p = < .001. Conclusion Casting only was the preferred treatment for all fractures (76%). Boys acquired DRFs more often than girls, with a peak age of 12 years. Younger children and boys with a complete fracture were more likely than older children and girls to receive a K-wire. Further research regarding indications for K-wiring of DRFs in the pediatric population is needed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.