Objectives: The use of video laryngoscopy (VL) may augment emergency pediatric intubations outside the operating room (OR). Our objective was to describe the proportion of use and complications with VL before and after implementation of a VL just-in-time training (JITT).Study design: This study was a retrospective chart review of pediatric intubations performed outside the OR at a single women and children's hospital from January 2015 to March 2020. Data were collected on patient age, intubation method, operator characteristics, adverse events, number of attempts, condition leading to intubation, and hospital location. Data were separated into pre-JITT (January 1, 2015 to April 31, 2018) and post-JITT (May 1, 2018 to March 1, 2020) periods. Descriptive statistics were used comparing pre-and post-JITT periods for VL use, and the complications of intubations with multiple attempts (IMAs) and intubations with one or more adverse events (AEs).Results: A total of 231 pediatric patients were intubated during the study period; 154 intubations in the pre-JITT and 77 intubations in the post-JITT periods. Pre-and post-JITT VL use was 17 (11%) and 17 (22%), respectively. With pre-JITT VL, there were four (23%) IMAs and zero (0%) intubation with one or more AE. With post-JITT VL, there were eight (47%) IMAs and one (6%) intubation with one or more AE. Conclusion:The proportion of emergency pediatric intubations using VL increased after the institution of a JITT. There was no significant change in IMAs and AEs. The infrequency of pediatric intubations makes drawing conclusions regarding the impact on IMAs and AEs challenging. JITT may increase VL use for emergency pediatric intubations outside the OR and may be considered for refresher training, especially during the coronavirus disease 2019 (COVID-19) pandemic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.