Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many—sometimes contradictory—observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device.
AimsUnloading-promoted reversal of heart failure (HF) allows long-term transplant-free outcome after ventricular assist device (VAD) removal. However, because few patients with chronic cardiomyopathy (CCM) were weaned from VADs (the majority only recently), the reliability of criteria used for weaning decisions to predict long-term post-weaning success is barely known. After 15 years of weaning experience, we assessed this issue.Methods and resultsIn 47 patients with CCM as the underlying cause for HF, who were part of a total of 90 patients weaned from bridge-to-transplant-designed VADs since 1995, we analysed data on cardiac morphology and function collected before VAD implantation, echocardiographic parameters recorded during ‘off-pump’ trials, duration of HF before implantation, and stability of recovery before and early after VAD removal. Post-weaning 5 year freedom from HF recurrence reached 66%. Only five patients (10.6%) died due to HF recurrence or weaning-related complications. Pre-explantation off-pump left ventricular ejection fraction (LVEF) of ≥50 and ≥45% revealed predictive values for cardiac stability lasting ≥5 years after VAD removal of 91.7 and 79.1%, respectively. With each unit of LVEF reduction, the risk of HF recurrence became 1.5 times higher. The predictive value of LVEF ≥45% also became >90% if additional parameters like pre-explantation LV size and geometry, stability of unloading-induced cardiac improvement before VAD removal, and HF duration before VAD implantation were also considered. Definite cut-off values for certain parameters (including tissue-Doppler-derived LV wall motion velocity) allowed formulation of weaning criteria with high predictability for post-weaning stability, also in patients with incomplete cardiac recovery.ConclusionsVentricular assist device removal in CCM patients is feasible and can be successful even after incomplete cardiac recovery. Parameters of pre-explantation cardiac function, LV size and geometry, their stability during final off-pump trials, and HF duration allow detection of patients with the potential to remain stable for >5 post-weaning years.
Background-During ventricular assist device (VAD) unloading, cardiac recovery is possible even in patients with chronic heart failure (HF). We sought parameters predictive of cardiac stability after VAD removal. Methods and Results-Among 81 patients weaned since March 1995, a homogenous group of 35 with idiopathic dilated cardiomyopathy weaned from left VADs was selected. We evaluated echo data obtained before left VAD implantation and during "off-pump" trials before explantation, histological changes, and serum anti-1-adrenoceptor-autoantibody disappearance during unloading, duration of unloading, and HF duration. Postweaning 10-year survival with native hearts reached 70.7Ϯ9.2%. During the first 5 years, HF recurred in 13 patients (37.1%). Only 6 (17.1%) died after HF recurrence or noncardiac complications related to left VAD explantation. Comparison of patients with and without long-term cardiac stability showed that stable patients were younger, HF history and recovery time during unloading shorter, and preweaning left ventricular assessment revealed higher left ventricular ejection fraction, lower short/long axis ratios, and higher end diastolic relative wall thicknesses. For left ventricular ejection fraction Ն45% at end diastolic diameter of Յ55 mm, predictive value for Ն5-year cardiac stability was 87.5%. Left ventricular ejection fraction time course during the first 6 postweaning months appeared predictive for long-term stability. HF history Ͼ5 years and preweaning instability of cardiac improvement appeared predictive for HF recurrence. Conclusions-In
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.