The goal of this study was to compare two surgical methods, the left carotid (LC) and the abdominal aorta (AA), for mouse instrumentation with telemetry devices, to determine the best method for measuring cardiovascular (CV) parameters by radiotelemetry in freely moving mice. Surgery success rate, postsurgical recovery rate, clinical parameters, CV data (baseline and response to nicotine) and circadian rhythm measurements were compared between these techniques. Brains of LC-implanted mice were evaluated for potential ischaemia by direct observation of the Circle of Willis anatomy and histopathology. For this purpose, a total of 31 CD-1 male mice were instrumented with PA C20 devices (10 with LC and 21 with AA). Mortality, morbidity, physical examination, body weight (BW), water and food consumption (W/FC), mean blood pressure (MBP) and heart rate (HR) were monitored daily during the recovery period (10 days). CV baseline data were recorded continuously during two periods of four days, and finally, both LC- and AA-implanted mice received an acute subcutaneous administration of 1 mg/kg nicotine; BP and HR were recorded during 5 h after nicotine administration. Results showed that, in LC-implanted mice, 80% survived surgery and recovered well. In contrast, only 57% of mice implanted with the AA technique survived surgery and some presented lethal complications. Both techniques had similar recovery times for BW and W/FC, comparable return to normal circadian rhythm (day 6 post-surgery) and similar CV baseline values. No significant differences were observed in CV response to nicotine between both groups of implanted CD-1 mice. No histopathological changes suggestive of ischaemia were noted in the brain of mice implanted in the LC. Six out of the eight LC-implanted mice remained in good health and had good pressure signal for at least 100 days post-surgery, while most of the AA-implanted mice lost the signal pressure within 14-49 days post-surgery. In conclusion, we believe that LC implantation in mice is superior to the AA technique and is more appropriate for long-term telemetry studies, especially for smaller (transgenic) animals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.