Three active detectors, Exradin A26 chamber, IBA RAZOR Nano chamber, and PTW 60019 microDiamond, were characterized for their use in electronic BrachyTherapy (eBT) dosimetry. The detectors were calibrated in terms of air kerma using the ISO “N” (narrow) and “TW” (therapy) X-rays series from 7.5 kV to 100 kV. The responses to mono-energetic photons and their uncertainties were determined with Bayesian parameter estimation, assuming a model that incorporated smoothness via a spline function. The response functions obtained this way are consistent with 18 calibration qualities simultaneously. This approach improves on the traditional procedure of associating the response to the mean energy of the corresponding spectra. The energy responses (with uncertainties) were obtained in 0.25 keV energy steps from 6 keV to 70 keV. With differences in magnitude due to their sizes and the nature of their active volumes, the energy responses of the 3 detectors follow a similar relative behaviour. Even when the response is far from flat at low energies, i.e. below about 20 keV, the determination of reliable energy dependence curves enables the use of these detectors for dosimetry in the vicinity of eBT units. The angular dependence of the three detectors with respect to beam incidence was also measured in air in a 180° range in steps of 10° using the Zeiss INTRABEAM system (50 kV). For both energy and angular response characterization, the detectors axis were aligned in parallel with the beam axis (end-on), since this is the expected orientation in further measurements of absorbed dose distribution in water around eBT sources at PTB. This work is an effort to provide traceability for detectors and measurement procedures for the determination of 3D dose distributions as part of the ongoing European EMPIR project “Primary standards and traceable measurement methods for X-ray emitting electronic brachytherapy devices” (PRISM-eBT)”.
In this work, a methodology to determine the absorbed dose rate to water distribution from electronic brachytherapy (eBT) units is suggested. It involves measuring directly in a full scatter water tank with small active detectors whose energy response at low X-ray photon energies have been previously characterized. Dose distributions of an INTRABEAM PRS 500 system in two configurations — bare needle and with the spherical applicator of 40 mm diameter — were measured in water using the Exradin A26 ionization chamber and the PTW 60019 microDiamond detector. The continuous energy response of these two detectors in terms of air kerma from 5 keV to 70 keV (eBT energy range) was available from a previous calibration at several X-ray radiation qualities. Here, it is converted to the response in absorbed dose to water using correction factors obtained with Monte Carlo (MC) particle transport simulations. The detectors were modelled using the MCNP code. The air kerma calibration factors were simulated and compared with measurements to refine and validate the models. A series of simulations of the experimental arrangement of the INTRABEAM and the detector were carried out for determining the system specific detector correction factors. These values are distance-dependent due to the steep dose gradient and the remarkable spectral changes around the eBT source in water. The dose rate with distance from the source, the radial and the polar distributions of the INTRABEAM are reported and compared with the manufacturers supplied data. This work is an effort to provide traceability for detectors and measurement procedures for the determination of 3D dose distributions as part of the European joint research project “Primary standards and traceable measurement methods for X-ray emitting electronic brachytherapy devices” (18NRM02 PRISM-eBT).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.