ECMO is a lifesaving option for patients with interstitial lung disease and acute respiratory failure provided they are candidates for lung transplantation. ECMO is not able to reverse the poor prognosis in patients that do not qualify for lung transplantation.
Background Even though bleeding and thromboembolic events are major complications of extracorporeal membrane oxygenation (ECMO), data on the incidence of venous thrombosis (VT) and thromboembolism (VTE) under ECMO are scarce. This study analyzes the incidence and predictors of VTE in patients treated with ECMO due to respiratory failure.MethodsRetrospective analysis of patients treated on ECMO in our center from 04/2010 to 11/2015. Patients with thromboembolic events prior to admission were excluded. Diagnosis was made by imaging in survivors and postmortem examination in deceased patients.ResultsOut of 102 screened cases, 42 survivors and 21 autopsy cases [mean age 46.0 ± 14.4 years; 37 (58.7 %) males] fulfilling the above-mentioned criteria were included. Thirty-four patients (54.0 %) underwent ECMO therapy due to ARDS, and 29 patients (46.0 %) with chronic organ failure were bridged to lung transplantation. Despite systemic anticoagulation at a mean PTT of 50.6 ± 12.8 s, [VT/VTE 47.0 ± 12.3 s and no VT/VTE 53.63 ± 12.51 s (p = 0.037)], VT and/or VTE was observed in 29 cases (46.1 %). The rate of V. cava thrombosis was 15/29 (51.7 %). Diagnosis of pulmonary embolism prevailed in deceased patients [5/21 (23.8 %) vs. 2/42 (4.8 %) (p = 0.036)]. In a multivariable analysis, only aPTT and time on ECMO predicted VT/VTE. There was no difference in the incidence of clinically diagnosed VT in ECMO survivors and autopsy findings.ConclusionsVenous thrombosis and thromboembolism following ECMO therapy are frequent. Quality of anticoagulation and ECMO runtime predicted thromboembolic events.
Background: Even though bleeding and thromboembolic events are major complications of extracorporeal membrane oxygenation (ECMO), data on the incidence of venous thrombosis (VT) and thromboembolism (VTE) under ECMO are scarce. This study analyzes the incidence and predictors of VTE in patients treated with ECMO due to respiratory failure. Methods:Retrospective analysis of patients treated on ECMO in our center from 04/2010 to 11/2015. Patients with thromboembolic events prior to admission were excluded. Diagnosis was made by imaging in survivors and postmortem examination in deceased patients.Results: Out of 102 screened cases, 42 survivors and 21 autopsy cases [mean age 46.0 ± 14.4 years; 37 (58.7 %) males] fulfilling the above-mentioned criteria were included. Thirty-four patients (54.0 %) underwent ECMO therapy due to ARDS, and 29 patients (46.0 %) with chronic organ failure were bridged to lung transplantation. Despite systemic anticoagulation at a mean PTT of 50.6 ± 12.8 s, [VT/VTE 47.0 ± 12.3 s and no VT/VTE 53.63 ± 12.51 s (p = 0.037)], VT and/or VTE was observed in 29 cases (46.1 %). The rate of V. cava thrombosis was 15/29 (51.7 %). Diagnosis of pulmonary embolism prevailed in deceased patients [5/21 (23.8 %) vs. 2/42 (4.8 %) (p = 0.036)]. In a multivariable analysis, only aPTT and time on ECMO predicted VT/VTE. There was no difference in the incidence of clinically diagnosed VT in ECMO survivors and autopsy findings.
Mortality in patients treated with extracorporeal membrane oxygenation (ECMO) is high. Therefore, it is crucial to better understand conditions that are associated with mortality in ECMO patients. In this retrospective analysis, we observed 51 patients treated with high-flow ECMO in 2013 and 2014 at our center. We recorded laboratory values and intensive care procedures. The hypothesis of bilirubin being a predictor of mortality during ECMO treatment was initially addressed. Therefore, laboratory values were obtained before initiation and at the time of highest bilirubin throughout the procedure. Receiver operating characteristic (ROC) curves and survival analysis were conducted. Our cohort consisted of patients with advanced age (median: 55 years; range: 22-76) and high mortality (26/51; 51%). Lactate, bilirubin, and NT-pro-BNP were significantly (p < 0.05) associated with mortality in univariable analyses. The cut-off values with highest Youden's index were bilirubin ≥10 mg/dl, lactate ≥2.25 mmol/L, and NT-pro-BNP ≥11,500 pg/ml. A multivariable analysis, revealed an area under the curve (AUC) of 0.85 (95% confidence interval [CI]: 0.74-0.97), sensitivity of 0.79, and specificity of 0.91. Bilirubin, lactate, and NT-pro-BNP were associated with mortality during ECMO treatment. However, laboratory values were only evaluated at the time of peak bilirubin.
The plasticizer di(2-ethylhexyl)phthalate (DEHP) is often used for PVC medical devices, that are also largely used for intensive care medical treatments, like extracorporeal membrane oxygenation (ECMO) therapy. Due to the toxicological potential of DEHP, the inner exposure of patients with this plasticizer is a strong matter of concern as many studies have shown a high leaching potential of DEHP into blood. In this study, the inner DEHP exposure of patients undergoing ECMO treatment was investigated. The determined DEHP blood levels of ECMO patients and the patients of the control group ranged from 31.5 to 1009 μg/L (median 156.0 μg/L) and from 19.4 to 75.3 μg/L (median 36.4 μg/L), respectively. MEHP blood levels were determined to range from < LOD to 475 μg/L (median 15.9 μg/L) in ECMO patients and from < LOD to 9.9 μg/L (median 3.7 μg/L) in the control group patients, respectively. Increased DEHP exposure was associated with the number of cannulas and membranes of the ECMO setting, whereas residual diuresis decreased the exposure. Due to the suspected toxicological potential of DEHP, its use in medical devices should be further investigated, in particular for ICU patients with long-term exposure to PVC, like in ECMO therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.