PurposeTo explore the safety and efficacy of PRT-201.MethodsRandomized, double-blind, placebo-controlled, single-dose escalation study of PRT-201 (0.0033 to 9 mg) applied after arteriovenous fistula (AVF) creation. Participants were followed for one year. The primary outcome measure was safety. Efficacy measures were the proportion with intra-operative increases in AVF outflow vein diameter or blood flow ≥25% (primary), changes in outflow vein diameter and blood flow, AVF maturation and lumen stenosis by ultrasound criteria and AVF patency.ResultsThe adverse events in the PRT-201 group (n=45) were similar to those in the placebo group (n=21). There were no differences in the proportion with ≥25% increase in vein diameter or blood flow, successful maturation or lumen stenosis. There was no statistically significant difference in primary patency between the dose groups (placebo n=21, Low Dose n=16, Medium Dose n=17 and High Dose n=12). In a subgroup analysis that excluded three participants with early surgical failures, the hazard ratio (HR) for primary patency loss of Low Dose compared with placebo was 0.38 (95% CI 0.10-1.41, P=0.15). In a Cox model, Low Dose (HR 0.27, 95% CI 0.04-0.79, P=0.09), white race (HR 0.17, 95% CI 0.03-0.79, P=0.02), and age <65 years (HR 0.25, CI 0.05-1.15, P=0.08) were associated (P<0.10) with a decreased risk of primary patency loss.ConclusionsPRT-201 was not different from placebo for safety or efficacy measures. There was a suggestion for improved AVF primary patency with Low Dose PRT-201 that is now being studied in a larger clinical trial.
Purpose
To explore the safety and efficacy of PRT-201 applied to the outflow vein of a newly created arteriovenous graft (AVG).
Methods
Randomized, double-blind, placebo-controlled, single-dose escalation study of PRT-201 (0.01 to 9 mg) applied to the graft-vein anastomosis and adjacent outflow vein immediately after AVG placement. The primary outcome measure was safety. The efficacy measures were intraoperative increases in outflow vein diameter and blood flow rate, primary unassisted patency, and secondary patency by dose groups (placebo, low, medium, high and All PRT-201).
Results
A total of 89 patients were treated (28 placebo and 61 PRT-201). There were no significant differences in the proportion of placebo and PRT-201 patients reporting adverse events. Intraoperative outflow vein diameter increased 5% (p=0.14) in the placebo group compared with 13% (p=0.01), 15% (p=0.07) and 12% (p<0.001), in the low, medium and high groups, respectively. The comparison between the high and placebo groups was marginally statistically significant (p=0.06). The intraoperative blood flow did not change in the placebo group, and increased in the low, medium and high groups by 19% (p=0.34), 36% (p=0.09) and 46% (p=0.02), respectively. The low group had the longest primary unassisted and secondary patency and the fewest procedures to restore or maintain patency; however, the differences between groups were not statistically significant.
Conclusions
PRT-201 was well tolerated and increased AVG intraoperative outflow vein diameter and blood flow. Low dose tended to increase secondary patency and decrease the rate of procedures to restore or maintain patency. Larger studies with these doses will be necessary to confirm these results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.