Bone preservation and physiological distribution of forces on the proximal femur are key elements in introducing a successful uncemented total hip replacement. In order to achieve this, in the mid 1990s, we developed an ultra short proximal loading custom-made component with a lateral flare, a high femoral neck osteotomy and without a diaphyseal stem. We report the outcome of 129 custom-made hydroxyapatite-coated uncemented short femoral components inserted into 109 patients between June 1995 and May 2004. The mean age of the patients was 51 years (21 to 71) and the mean follow-up was eight years (4.9 to 14.1). Bone behaviour around the implant was studied on the post-operative radiographs. The mean Harris hip score improved from 44 (8 to 66) pre-operatively to 95 (76 to 100) at final follow-up. The Western Ontario MacMaster University Osteoarthritis index was 93 of 100 at final review. None of the patients reported thigh pain. A total of five hips were revised, three for polyethylene liner exchange and two for complete revision of the acetabular component. No femoral components were revised. The radiological changes in the proximal femur were generally good, as evidenced by spot welds both on the medial and lateral aspects of the femur. No component migrated. The presence of a lateral flare and use of a high osteotomy of the femoral neck provided good clinical and radiological results. The absence of a diaphyseal portion of the stem did not impair stability.
Background and purpose Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on periprosthetic bone remodeling using a specifically developed protocol of analysis with 5 periprosthetic regions of interest (ROIs).Patients and methods Bone mineral density (BMD) was evaluated in 37 patients in the plateau stage, 3 years after THA. Two femoral implants featuring conceptually new designs and surgical technique were tested: types 1 and 2, characterized by extremely short stem and virtual absence of distal stem, respectively.Results We found that progressive shortening of the femoral stem produces more proximal loading, which effectively preserves metaphyseal bone stock and increases periprosthetic BMD in the medial ROIs over time. In the type 2 group, higher absolute BMD values were observed in medial ROIs 4 and 5. No differences were found in ROIs 1, 2, and 3.Interpretation This study shows the flexibility of DXA in adapting the protocol of periprosthetic analysis to the specific requirements of new implant designs, and it shows its high sensitivity in evaluation of the biological response of bone to changes in implant shape.
We performed a randomised controlled study to compare heparin with the A-V Impulse System in the prevention of deep-vein thrombosis (DVT) in 132 consecutive patients undergoing total hip replacement. After the operation, all patients had compression stockings, 65 were treated with calcium heparin and 67 with the intermittent plantar pump. DVT was diagnosed by Doppler ultrasound and thermography, followed by phlebography. There were 23 cases of DVT (35.4%) in the heparin group, with 16 m& jor and seven minor thromboses. In the impulse pump group there were nine cases (13.4%) with three ma jor and six minor thromboses. The differences for all thromboses and for major thromboses were both significant at p < 0.005. In the heparin group there was one fatal pulmonary embolism and nine patients (13.8%) had excessive bleeding or wound haematomas, as against none in the impulse pump group.
Bone stock preservation is crucial when performing THR in young patients. Following this philosophy, an original ultra-short custom-made implant with extensive proximal load transfer was developed. It presents three very innovative features: absence of the diaphyseal portion of the stem, a well defined lateral flare with load transfer on the lateral column of the femur and a very high femoral neck cut. These innovations resulted in a very conservative implant both of the bone stock and the soft tissues. In this study we reviewed the X-rays of 111 patients with 131 primary total hip replacements performed with this implant. The average pain score using the Harris Hip Score system, at an average of five years after surgery, was 42 of 44 points; 95 per cent (124) of the patients had no or slight pain. We had no cases of thigh pain. None of the patients required a femoral stem revision. Two cases had to be re-operated for polyethylene liner exchange but the femoral implant was stable and left in place. At five years, all implants appeared radiographically stable with well maintained proximal bone stock. It was concluded that the geometry of this implant provides significant initial stability, which seems to be preserved throughout a long follow-up period. This study validates the assumption that torsional loads can be controlled even without the diaphyseal portion of the stem and that neck preservation combined with lateral flare support guarantees a more natural loading of the femur.
BackgroundAnatomic short femoral prostheses with a prominent lateral flare have the potential to reduce stress-shielding in the femur through a more physiological stress distribution to the proximal femur. We present the design rationale of a new short uncemented, proximally fixed anatomic femoral implant and the study design of a prospective multi-centre trial to collect long-term patient outcome and radiographic follow up data.MethodsA prospective surveillance study (trial registry NCT00208555) in four European centres (UK, Italy, Spain and Germany) with a follow up period of 15 years will be executed. The recruitment target is 200 subjects, patients between the ages of 18 and 70 admitted for primary cementless unilateral THA will be included. The primary objective is to evaluate the five-year survivorship of the new cementless short stem. The secondary objectives of this investigation are to evaluate the long term survivorship and the clinical performance of the implant, the impact on the subjects health related Quality of Life and the affect of the prosthesis on bone mineral density. Peri- and postoperative complications will be registered. Clinical and radiographic evaluation of prosthesis positioning will be done post-operatively and at 3, 6, 12, 24, 60, 120 and 180 months follow up.DiscussionShortening of the distal stem can maximise bone and soft tissue conservation. New stem types have been designed to improve the limitations of traditional implants in primary THA. A new, uncemented femoral short stem is introduced in this paper. A long-term follow up study has been designed to verify stable fixation and to research into the clinical outcome. The results of this trial will be presented as soon as they become available.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.