Feline leukaemia virus (FeLV) is a retrovirus associated with fatal disease in progressively infected cats. While testing/removal and vaccination led to a decreased prevalence of FeLV, recently, this decrease has reportedly stagnated in some countries. This study aimed to prospectively determine the prevalence of FeLV viraemia in cats taken to veterinary facilities in 32 European countries. FeLV viral RNA was semiquantitatively detected in saliva, using RT-qPCR as a measure of viraemia. Risk and protective factors were assessed using an online questionnaire to report geographic, demographic, husbandry, FeLV vaccination, and clinical data. The overall prevalence of FeLV viraemia in cats visiting a veterinary facility, of which 10.4% were shelter and rescue cats, was 2.3% (141/6005; 95% CI: 2.0%–2.8%) with the highest prevalences in Portugal, Hungary, and Italy/Malta (5.7%–8.8%). Using multivariate analysis, seven risk factors (Southern Europe, male intact, 1–6 years of age, indoor and outdoor or outdoor-only living, living in a group of ≥5 cats, illness), and three protective factors (Northern Europe, Western Europe, pedigree cats) were identified. Using classification and regression tree (CART) analysis, the origin of cats in Europe, pedigree, and access to outdoors were important predictors of FeLV status. FeLV-infected sick cats shed more viral RNA than FeLV-infected healthy cats, and they suffered more frequently from anaemia, anorexia, and gingivitis/stomatitis than uninfected sick cats. Most cats had never been FeLV-vaccinated; vaccination rates were indirectly associated with the gross domestic product (GDP) per capita. In conclusion, we identified countries where FeLV was undetectable, demonstrating that the infection can be eradicated and highlighting those regions where awareness and prevention should be increased.
Background: The Guardian REAL-Time is a continuous glucose-monitoring system (CGMS) recently developed to provide instantaneous interstitial glucose concentrations; the system does not require a monitor being fixed to the animal.Hypothesis: The CGMS provides accurate and reproducible real-time readings of glucose concentration in cats. Animals: Thirty-two diabetic cats, 2 cats with suspected insulinoma, and 5 healthy cats. Methods: Prospective, observational study. CGMS accuracy was compared with a reference glucose meter at normal, high, and low blood glucose concentrations using error grid analysis. Reading variability of 2 simultaneously used CGMS was determined in diabetic cats by calculating correlation and percentage of concordance of paired data at different glycemic ranges. The time interval between increasing glycemia and a rise in interstitial fluid glucose measured by the CGMS was assessed in healthy cats receiving glucose IV; the time point of maximal increase in interstitial glucose concentrations was calculated.Results: The CGMS was 100, 96.1, and 91.0% accurate at normal, high, and low blood glucose concentrations. Measurements deviated from reference by À12.7 AE 70.5 mg/dL at normal, À12.1 AE 141.5 mg/dL at high, and À1.9 AE 40.9 mg/dL at low glucose concentrations. Overall, paired CGMS readings correlated significantly (r 5 0.95, P o .0001) and concordance was 95.7%. The median delay after IV administration of glucose to an increase in interstitial glucose was 11.4 minutes (range: 8.8-19.7 minutes).Conclusions and Clinical Importance: Although some readings substantially deviated from reference values, the CGMS yields reproducible results, is clinically accurate in cats with hyperglycemia and euglycemia, and is slightly less accurate if blood glucose concentrations are low. Rapidly increasing interstitial glucose after a glycemic rise suggests that the CGMS is suitable for real-time measurement under clinical conditions.
Portable blood glucose meters (PBGMs) are useful in the management of diabetes mellitus in cats. In the present study we compared the performance of two PBGMs: the AlphaTRAK (Abbott Animal Health, Maidenhead, England) specifically developed for dogs and cats, and the Ascensia ELITE (Bayer HealthCare, Zurich, Switzerland) developed for humans. Quality parameters, including precision and accuracy, were better for the AlphaTRAK meter compared to Ascensia ELITE. While the AlphaTRAK meter results did not differ from the reference method, results from the Ascensia ELITE were significantly (P<0.001) lower. The superior performance of the AlphaTRAK meter supports its use to monitor blood glucose levels in cats.
Background: Diabetic ketoacidosis (DKA) has long been considered a key clinical feature of type-1 diabetes mellitus (DM) in humans although. An increasing number of cases of ketoacidosis have been reported in people with type-2 DM.Hypothesis/Objectives: Cats initially diagnosed with DKA can achieve remission from diabetes. Cats with DKA and diabetic remission are more likely to have been administered glucocorticoids before diagnosis.Animals: Twelve cats with DKA and 7 cats with uncomplicated DM. Methods: Retrospective case review. Medical records of cats presenting with DKA or DM were evaluated. Diabetic remission was defined as being clinically unremarkable for at least 1 month after insulin withdrawal. The cats were assigned to 1 of 3 groups: (1) cats with DKA and diabetic remission; (2) cats with DKA without diabetic remission; and (3) cats with DM and diabetic remission.Results: Seven cats with DKA had remission from diabetes. These cats had significantly higher concentrations of leukocytes and segmented neutrophils, and significantly lower concentrations of eosinophils in blood and had pancreatic disease more often than did cats with uncomplicated DM and diabetic remission. With regard to pretreatment, 3/7 cats in group 1, 1/5 cats in group 2, and 1/7 cats in group 3 had been treated with glucocorticoids.Conclusions and Clinical Importance: Remission of DM in cats presenting with DKA is possible. Cats with DKA and remission have more components of a stress leucogram, pancreatic disease, and seemed to be treated more often with glucocorticoids than cats with uncomplicated DM and diabetic remission.
Adjustments in insulin dose based on glucose profiles generated with the CGMS are similar to those based on the PBGM. The common occurrence of lower nadirs recorded with the CGMS suggests that this device detects hypoglycemic periods that are not identified with the PBGM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.