DREAMS (DFM Rule EvAluation using Manufactured Silicon) is a comprehensive methodology for evaluating the yield-preserving capabilities of a set of DFM (design for manufacturability) rules using the results of logic diagnosis performed on failed ICs. DREAMS is an improvement over prior art in that the distribution of rule violations over the diagnosis candidates and the entire design are taken into account along with the nature of the failure (e.g., bridge versus open) to appropriately weight the rules. Silicon and simulation results demonstrate the efficacy of the DREAMS methodology. Specifically, virtual data is used to demonstrate that the DFM rule most responsible for failure can be reliably identified even in light of the ambiguity inherent to a nonideal diagnostic resolution, and a corresponding rule-violation distribution that is counter-intuitive. We also show that the combination of physically-aware diagnosis and the nature of the violated DFM rule can be used together to improve rule evaluation even further. Application of DREAMS to the diagnostic results from an in-production chip provides valuable insight in how specific DFM rules improve yield (or not) for a given design manufactured in particular facility. Finally, we also demonstrate that a significant artifact of DREAMS is a dramatic improvement in diagnostic resolution. This means that in addition to identifying the most ineffective DFM rule(s), validation of that outcome via physical failure analysis of failed chips can be eased due to the corresponding improvement in diagnostic resolution.
Abstract⎯On-chip analog self-healing requires low-cost sensors to accurately measure various performance metrics. In this paper, we propose a novel approach of indirect performance sensing based upon Bayesian model fusion (BMF) to facilitate inexpensive-yet-accurate on-chip performance measurement. A 25GHz differential Colpitts voltage-controlled oscillator (VCO) designed in a 32nm CMOS SOI process is used to validate the proposed indirect performance sensing and self-healing methodology. Our silicon measurement results demonstrate that the parametric yield of the VCO is improved from 0% to 69.17% for a wafer after the proposed self-healing is applied.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.