Background Soluble Klotho has multiple systemic salutary effects. In animals, both acute and chronic kidney disease models display systemic Klotho deficiency. As such, there is considerable interest in investigating soluble Klotho as a biomarker in patients with different types and severity of kidney diseases. Unfortunately, there remains uncertainty regarding the best method to measure soluble Klotho in human serum samples. Methods Using human serum samples obtained from several clinical cohorts with a wide range of kidney function, we measured soluble Klotho using a commercial enzyme-linked immunosorbent assay (ELISA) as well as with an immunoprecipitation–immunoblot (IP–IB) assay utilizing a synthetic antibody with high affinity and specificity for Klotho. Recovery of spiking with a known amount of exogenous Klotho was tested. A subset of samples was analyzed with and without the addition of a protease inhibitor cocktail at the time of collection or after the first freeze–thaw cycle to determine if these maneuvers influenced performance. Results The IP–IB assay was superior to the ELISA at recovery of exogenous Klotho (81–115% versus 60–81%) across the spectrum of kidney function. Klotho measurements by IP–IB were highly correlated with estimated glomerular filtration rate (eGFR) (R = 0.80, P < 0.001) in comparison with the commercial ELISA, which exhibited minimal correlation with eGFR (R = 0.18, P = 0.12). Use of a protease inhibitor cocktail neither improved nor impaired performance of the IP–IB assay; however, subsequent freeze–thaw cycle resulted in a significant reduction in Klotho recovery and dissipated the correlation between Klotho levels and eGFR. With the ELISA, the use of protease inhibitor cocktail resulted in an increase in intrasubject variability. Conclusions The IP–IB assay is preferable to the commercial ELISA to measure soluble Klotho concentrations in never-thawed serum samples of humans with varying severity of kidney disease. However, due to the labor-intensive nature of the IP–IB assay, further research is needed to secure an assay suitable for high-throughput work.
BackgroundSymptoms of sleep apnea are markedly increased in children exposed to smoke from biomass fuels and are reduced by kitchen stoves that improve indoor biomass pollution. However, the impact of adherence to the use of improved stoves has not been critically examined.MethodsSleep-related symptom questionnaires were obtained from children <15 years of age in 56 families residing in the communities of Lliupapuquio, Andahuaylas province in Peru before and 2 years after installation of less-polluting Inkawasi cooking stoves.Results82 children with lifetime exposures to indoor fuel pollution were included. When compared to those alternating between both types of stoves or those using traditional stoves only, those children who exclusively used Inkawasi cooking stoves showed significant improvements in sleep and respiratory related symptoms, but some minor albeit significant improvements occurred when both stoves were concomitantly used.ConclusionsImprovements in respiratory and sleep-related symptoms associated with elevated indoor biomass pollution occur only following implementation and exclusive utilization of improved kitchen stoves.
Background Preliminary studies have suggested that the renin-angiotensin system is activated in critical illness and associated with mortality and kidney outcomes. We sought to assess in a larger, multicenter study the relationship between serum renin and Major Adverse Kidney Events (MAKE) in intensive care unit (ICU) patients. Methods Prospective, multicenter study at two institutions of patients with and without acute kidney injury (AKI). Blood samples were collected for renin measurement a median of 2 days into the index ICU admission and 5–7 days later. The primary outcome was MAKE at hospital discharge, a composite of mortality, kidney replacement therapy, or reduced estimated glomerular filtration rate to ≤ 75% of baseline. Results Patients in the highest renin tertile were more severely ill overall, including more AKI, vasopressor-dependence, and severity of illness. MAKE were significantly greater in the highest renin tertile compared to the first and second tertiles. In multivariable logistic regression, this initial measurement of renin remained significantly associated with both MAKE as well as the individual component of mortality. The association of renin with MAKE in survivors was not statistically significant. Renin measurements at the second time point were also higher in patients with MAKE. The trajectory of the renin measurements between time 1 and 2 was distinct when comparing death versus survival, but not when comparing MAKE versus those without. Conclusions In a broad cohort of critically ill patients, serum renin measured early in the ICU admission is associated with MAKE at discharge, particularly mortality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.