Purpose: Angiographic equipment is a key component of healthcare infrastructure, used for endovascular procedures throughout the body. The literature on adverse events related to this technology is limited. The purpose of this study was to analyze adverse events related to angiographic devices from the US Food and Drug Administration’s Manufacturer and User Facility Device Experience (MAUDE) database. Methods: MAUDE data on angiographic imaging equipment from July 2011 to July 2021 were extracted. Qualitative content analysis was performed, a typology of adverse events was derived, and this was used to classify the data. Outcomes were assessed using the Healthcare Performance Improvement (HPI) and Society of Interventional Radiology (SIR) adverse event classifications. Results: There were 651 adverse events reported. Most were near misses (67%), followed by precursor safety events (20.5%), serious safety events (11.2%), and unclassifiable (1.2%). Events impacted patients (42.1%), staff (3.2%), both (1.2%), or neither (53.5%). The most common events associated with patient harm were intra-procedure system shut down, foot pedal malfunction, table movement malfunction, image quality deterioration, patient falls, and fluid damage to system. Overall, 34 (5.2%) events were associated with patient death; 18 during the procedure and 5 during patient transport to another angiographic suite/hospital due to critical failure of equipment. Conclusion: Adverse events related to angiographic equipment are rare; however, serious adverse events and deaths have been reported. This study has defined a typology of the most common adverse events associated with patient and staff harm. Increased understanding of these failures may lead to improved product design, user training, and departmental contingency planning.
The differential diagnosis of isolated pleural effusion is very wide. Unilateral hemothorax carry the same wide differentials. Taking systematic approach can lead to diagnosis in the majority of cases. We presented a case of unilateral hemothroax in a gentleman with minimal symptoms and unhelpful clinical exam. Despite his low risk, he turned to have type B aortic dissection presenting as left sided hemothorax, which is a rare presentation. We presented the clinical course the patient went through and finished with brief discussion on thoracic aortic dissection and its relation to hemothorax.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.