This study adopts a multi-disciplinary optimization design method based on an approximation model to improve the comprehensive performance of axial-flow pump impellers and fully consider the interaction and mutual influences of the hydraulic and structural designs. The lightweight research on axial-flow pump impellers takes the blade mass and efficiency of the design condition as the objective functions and the head, efficiency, maximum stress value, and maximum deformation value under small flow condition as constraints. In the optimization process, the head of the design condition remains unchanged or varies in a small range. Results show that the mass of a single blade was reduced from 0.947 to 0.848 kg, reaching a decrease of 10.47%, and the efficiency of the design condition increased from 93.91% to 94.49%, with an increase rate of 0.61%. Accordingly, the optimization effect was evident. In addition, the error between the approximate model results and calculation results of each response was within 0.5%, except for the maximum stress value. This outcome shows that the accuracy of the approximate model was high, and the analysis result is reliable. The results provide guidance for the optimal design of axial-flow pump impellers.
By means of numerical simulation and experimental verification, this article investigates the hydraulic performance and pressure fluctuation of a tank-style axial-flow pump device. With orthogonal test, 16 schemes are designed concerning the different flow conditions of the inlet and outlet passages, and simulated calculations are done; then the non-steady numerical simulation of pressure fluctuation is carried out for the optimized pump device; a model test finally verifies the reliability of the simulated numerical values of the optimized scheme. The results show that using the orthogonal test, an optimized scheme of the inlet and outlet passages can be obtained; compared with the initial scheme, the optimized one reduces the hydraulic loss by 1.3 cm in the inlet passage and 7.96 cm in the outlet passage; numerical simulation witnesses the highest pump operating efficiency of 70.04%, efficiency of 66.82% with the design head of 1.36 m, and the corresponding flow of 34.31 m 3 /s; the model test verifies all the simulated values of the optimized scheme with the highest pump operating efficiency reaching 71.5% and the test efficiency arriving at about 64% when the design head is 1.36 m. Meanwhile, the highest pressure fluctuation appears at the entrance of the impeller; the main frequency of the impeller and guide vane pressure fluctuation is 5 Hz depending on the frequency of the blade. This study offers reference for similar pump station project.
The formation of an inlet vortex seriously restricts axial-flow pump device performance and poses a great threat to the safe and stable operation of the entire system. In this study, the change trends of an inlet vortex and its influence on an axial-flow pump are investigated numerically and experimentally in a vertical axial-flow pump device. Four groups of fixed vortex generators (VGs) are installed in front of the impeller to create stable vortices at the impeller inlet. The vortex influence on the performance of pump device is qualitatively and quantitatively analyzed. The vortex patterns at different positions and moments in the pump device are explored to reveal the vortex shape change trend in the impeller and the pressure fluctuation induced by the vortex. The reliability and accuracy of steady and unsteady numerical results are verified by external characteristics and pressure fluctuation experimental results. Results show that it is feasible to install VGs before the impeller inlet to generate stable vortices. The vortex disturbs the inlet flow fields of the impeller, resulting in significant reductions of the axial velocity weighted average angle and the axial velocity uniformity. The vortex increases the inlet passage hydraulic loss and reduces the impeller efficiency, while it only slightly affects the guide vane and outlet passage performance. The vortex causes a low-frequency pressure pulsation and interacts with the impeller. The closer the vortex is to the impeller inlet, the more significant the impeller influence on the vortex. The blade cuts off the vortex in the impeller; afterwards, the vortex follows the blade rotation, and its strength weakens.
In order to explore the transient characteristics of the large-scale vertical siphon axial flow pumping station during the start-up and exhaust process, numerical simulations were carried out on the start-up process of the axial flow pumping station under the two starting modes of pre-opening the vacuum breaking valve and keeping the vacuum breaking valve closed. The calculation results show that during the start-up phase of the unit, the flow separation phenomenon of the impeller channel of the pump device with the vacuum breaking valve closed is serious, the large-scale vortex in the guide vane blocks the flow channel, and the instantaneous impact on the blade surface is strong. The flow field of the pump device with pre-open vacuum failure valve is obviously less affected by the instantaneous impact characteristics during the start-up of the pump. The range of high entropy production area in the impeller channel is reduced, the duration of high entropy production area is significantly shortened, and the instantaneous impact on the blade surface is weak. Under the two starting modes, the internal flow field of the pump device is similar in the evolutionary law. The unstable flow phenomenon of the pump device is most prominent in the weir flow stage. The maximum instantaneous impact on the blade surface also mainly occurs in the weir flow stage. A very small part of the remaining gas in the siphon formation stage is difficult to discharge and takes a long time. After the pump device is exhausted and enters a stable operation state, the external characteristic parameters are in good agreement with the test results. Compared with the starting method in which the vacuum breaking valve is kept closed, the method of pre-opening the vacuum breaking valve reduces the maximum starting head by 20% and the exhaust time by 43%. The pre-open vacuum breaking valve effectively avoids the system instability caused by the start-up and exhaust of the pump device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.