Calibrated Automated Thrombography (CAT) has been widely used to assess in vitro thrombin generation as an informative intermediary phenotype of coagulation. Interlaboratory exercises have documented a worrisome poor reproducibility. There are some data on the normalisation with an appropriate external reference plasma (RP). This multicentre study of the French-speaking CAT Club aimed at providing further evidence for the usefulness of such a normalisation
We aimed to identify risk factors for recurrent venous thromboembolism (VTE) after unprovoked pulmonary embolism.Analyses were based on the double-blind randomised PADIS-PE trial, which included 371 patients with a first unprovoked pulmonary embolism initially treated during 6 months who were randomised to receive an additional 18 months of warfarin or placebo and followed up for 2 years after study treatment discontinuation. All patients had ventilation/perfusion lung scan at inclusion ( at 6 months of anticoagulation).During a median follow-up of 41 months, recurrent VTE occurred in 67 out of 371 patients (6.8 events per 100 person-years). In main multivariate analysis, the hazard ratio for recurrence was 3.65 (95% CI 1.33-9.99) for age 50-65 years, 4.70 (95% CI 1.78-12.40) for age >65 years, 2.06 (95% CI 1.14-3.72) for patients with pulmonary vascular obstruction index (PVOI) ≥5% at 6 months and 2.38 (95% CI 1.15-4.89) for patients with antiphospholipid antibodies. When considering that PVOI at 6 months would not be available in practice, PVOI ≥40% at pulmonary embolism diagnosis (present in 40% of patients) was also associated with a 2-fold increased risk of recurrence.After a first unprovoked pulmonary embolism, age, PVOI at pulmonary embolism diagnosis or after 6 months of anticoagulation and antiphospholipid antibodies were found to be independent predictors for recurrence.
Acute traumatic coagulopathy (ATC) is an acute and endogenous mechanism triggered by the association of trauma and hemorrhage. Several animal models have been developed, but some major biases have not yet been identified. Our aim was to develop a robust and clinically relevant murine model to study this condition. Anesthetized adult Sprague Dawley rats were randomized into 4 groups: C, control; T, trauma; H, hemorrhage; TH, trauma and hemorrhage (n = 7 each). Trauma consisted of laparotomy associated with four-limb and splenic fractures. Clinical variables, ionograms, arterial and hemostasis blood tests were compared at 0 and 90 min. ATC and un-compensated shock were observed in group TH. In this group, the rise in prothrombin time and activated partial thromboplastin was 29 and 40%, respectively. Shock markers, compensation mechanisms and coagulation pathways were all consistent with human pathophysiology. The absence of confounding factors, such as trauma-related bleeding or dilution due to trans-capillary refill was verified. This ethic, cost effective and bias-controlled model reproduced the specific and endogenous mechanism of ATC and will allow to identify potential targets for therapeutics in case of trauma-related hemorrhage.
P2Y12 receptor inhibitors are antiplatelet agents commonly prescribed in the treatment of coronary artery disease. Their efficacy can be limited by high on-treatment platelet reactivity (HPR), which can be evaluated by different biological assays. Most commonly, HPR is evaluated by flow cytometric vasodilator-stimulated phosphoprotein-phosphorylation (VASP-P) assay, which can be time consuming. To evaluate the potential interest of novel technologies, we compared four different assays. Ninety patients receiving P2Y12 inhibitors were included. Four technologies were evaluated: the current standard test measuring VASP-P by flow cytometry, the historical reference test based on light transmittance aggregation (LTA), and two relatively novel techniques: whole blood multiple electrode aggregometry (MEA) and platelet function analyzer (PFA), which are less time consuming. The three latter tests were compared with the VASP-P assay as a reference using receiver operating characteristics (ROC) analysis: LTA has an excellent comparability with the VASP test (ROC AUC > 0.9); the other two tests (multiplate and PFA) have only satisfactory comparability (ROC AUC around 0.7) and therefore may not replace the VASP "gold standard" test, if importance is attached to a quantitative assessment of the substitution parameter of VASP. Nevertheless, if a binary approach of the anti-aggregation result is sought, then one can conclude that the three tests are equivalent since Cohen's kappa coefficients are very close for the three tests (k = 0.548 for LTA; k = 0.554 for MEA; k = 0.570 for PFA/P2Y), and a similar proportion of patients are misclassified (15% for LTA, 14% for MEA, and 13.6% for PFA). Discriminant factor analysis using all the parameters provided by each test did not improve the diagnostic performance of MEA or PFA. In conclusion, only LTA shows a good comparability to the VASP assay using ROC curve analysis, probably because misclassified patients have results close to the cutoff values. All three tests have moderate agreement regarding the classification of patients as responders to P2Y12 inhibition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.