The HeartLogic multisensor index and alert algorithm provides a sensitive and timely predictor of impending HF decompensation. (Evaluation of Multisensor Data in Heart Failure Patients With Implanted Devices [MultiSENSE]; NCT01128166).
Background:
The Subcutaneous ICD (S-ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, less left ventricular dysfunction and received more inappropriate shocks (IAS) than in typical transvenous (TV)-ICD trials. The UNTOUCHED trial was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms.
Methods:
Primary prevention patients with left ventricular ejection fraction (LVEF) ≤ 35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥ 250 beats per minute (bpm) and morphology discrimination for rates ≥200 and < 250 bpm. Patients were followed for 18 months. The primary endpoint was the IAS free rate compared to a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study. Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of endpoints.
Results:
S-ICD implant was attempted in 1116 patients and 1111 patients were included in post-implant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% women, 23.4% black race, 53.5% with ischemic heart disease, 87.7% with symptomatic heart failure and a mean LVEF of 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (Lower confidence limit LCL 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the three-incision technique, no history of atrial fibrillation, and ischemic etiology. The 18-month all cause shock free rate was 90.6% (LCL 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication free rate at 18 months was 92.7%.
Conclusions:
This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of co-morbidities in comparison to earlier S-ICD trials. The inappropriate shock rate (3.1% at one year) is the lowest reported for the S-ICD and lower than many TV ICD studies using contemporary programming to reduce IAS.
Clinical Trial Registration:
URL https://clinicaltrials.gov Unique Identifier NCT02433379
COVID-19 outbreak had a major impact on the organization of care in Italy, and a survey to evaluate provision of for arrhythmia during COVID-19 outbreak (March-April 2020) was launched. A total of 104 physicians from 84 Italian arrhythmia centres took part in the survey. The vast majority of participating centres (95.2%) reported a significant reduction in the number of elective pacemaker implantations during the outbreak period compared to the corresponding two months of year 2019 (50.0% of centres reported a reduction of > 50%). Similarly, 92.9% of participating centres reported a significant reduction in the number of implantable cardioverter-defibrillator (ICD) implantations for primary prevention, and 72.6% a significant reduction of ICD implantations for secondary prevention (> 50% in 65.5 and 44.0% of the centres, respectively). The majority of participating centres (77.4%) reported a significant reduction in the number of elective ablations (> 50% in 65.5% of the centres). Also the interventional procedures performed in an emergency setting, as well as acute management of atrial fibrillation had a marked reduction, thus leading to the conclusion that the impact of COVID-19 was disrupting the entire organization of health care, with a massive impact on the activities and procedures related to arrhythmia management in Italy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.