The rapid insurgence and spread of coronavirus disease 2019 (COVID-19) exceeded the limit of the intensive care unit (ICU) contingency plan of the Maggiore della Carità University Hospital (Novara, Italy) generating a crisis management condition. This brief report describes how a prompt response to the sudden request of invasive mechanical ventilation (IMV) was provided by addressing the key elements of health care system surge capacity from contingency to crisis. In a short time and at a relatively low cost, a structural modification of a hospital aisle allowed to convert the general ICU into a COVID-19 unit, increasing the number of COVID-19 critical care beds by 107%.
Background Driving pressure can be readily measured during assisted modes of ventilation such as pressure support ventilation (PSV) and neurally adjusted ventilatory assist (NAVA). The present prospective randomized crossover study aimed to assess the changes in driving pressure in response to variations in the level of assistance delivered by PSV vs NAVA. Methods 16 intubated adult patients, recovering from hypoxemic acute respiratory failure (ARF) and undergoing assisted ventilation, were randomly subjected to six 30-min-lasting trials. At baseline, PSV (PSV100) was set with the same regulation present at patient enrollment. The corresponding level of NAVA (NAVA100) was set to match the same inspiratory peak of airway pressure obtained in PSV100. Therefore, the level of assistance was reduced and increased by 50% in both ventilatory modes (PSV50, NAVA50; PSV150, NAVA150). At the end of each trial, driving pressure obtained in response to four short (2-3 s) end-expiratory and end-inspiratory occlusions was analyzed. Results Driving pressure at PSV50 (6.6 [6.1-7.8] cmH 2 O) was lower than that recorded at PSV100 (7.9 [7.2-9.1] cmH 2 O, P = 0.005) and PSV150 (9.9 [9.1-13.2] cmH 2 O, P < 0.0001). In NAVA, driving pressure at NAVA50 was reduced compared to NAVA150 (7.7 [5.1-8.1] cmH 2 O vs 8.3 [6.4-11.4] cmH 2 O, P = 0.013), whereas there were no changes between baseline and NAVA150 (8.5 [6.3-9.8] cmH 2 O vs 8.3 [6.4-11.4] cmH 2 O, P = 0.331, respectively). Driving pressure at PSV150 was higher than that observed in NAVA150 (P = 0.011). Conclusions NAVA delivers better lung-protective ventilation compared to PSV in hypoxemic ARF patients. Trial registration number and date of registration The present trial was prospectively registered at www.clini catri als.gov (NCT03719365) on
Background Esophageal balloon calibration was proposed in acute respiratory failure patients to improve esophageal pressure assessment. In a clinical setting characterized by a high variability of abdominal load and intrathoracic pressure (i.e., pelvic robotic surgery), the authors hypothesized that esophageal balloon calibration could improve esophageal pressure measurements. Accordingly, the authors assessed the impact of esophageal balloon calibration compared to conventional uncalibrated approach during pelvic robotic surgery. Methods In 30 adult patients, scheduled for elective pelvic robotic surgery, calibrated end-expiratory and end-inspiratory esophageal pressure, and the associated respiratory variations were obtained at baseline, after pneumoperitoneum–Trendelenburg application, and with positive end-expiratory pressure (PEEP) administration and compared to uncalibrated values measured at 4-ml filling volume, as per manufacturer recommendation. Data are expressed as median and [25th, 75th percentile]. Results Ninety calibrations were successfully performed. Chest wall elastance worsened with pneumoperitoneum–Trendelenburg and PEEP (19.0 [15.5, 24.6] and 16.7 [11.4, 21.7] cm H2O/l) compared to baseline (8.8 [6.3, 9.8] cm H2O/l; P < 0.0001 for both comparisons). End-expiratory and end-inspiratory calibrated esophageal pressure progressively increased from baseline (3.7 [2.2, 6.0] and 7.7 [5.9, 10.2] cm H2O) to pneumoperitoneum–Trendelenburg (6.2 [3.8, 10.2] and 16.1 [13.1, 20.6] cm H2O; P = 0.014 and P < 0.001) and PEEP (8.8 [7.7, 15.6] and 18.9 [16.3, 22.0] cm H2O; P < 0.0001 vs. baseline for both comparison; P < 0.001 and P = 0.002 vs. pneumoperitoneum–Trendelenburg) and, at each study step, they were persistently lower than uncalibrated esophageal pressure (P < 0.0001 for all comparisons). Overall, difference among uncalibrated and calibrated esophageal pressure was 5.1 [3.8, 8.4] cm H2O at end-expiration and 3.8 [3.0, 6.3] cm H2O at end-inspiration. Uncalibrated esophageal pressure swing was always lower than calibrated one (P < 0.0001 for all comparisons) with a difference of −1.0 [−1.8, −0.4] cm H2O. Conclusions In a clinical setting with variable chest wall mechanics, uncalibrated measurements substantially overestimated absolute values and underestimated respiratory variations of esophageal pressure. Calibration could substantially improve mechanical ventilation guided by esophageal pressure. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
In patients intubated for hypoxemic acute respiratory failure (ARF) related to novel coronavirus disease (COVID-19), we retrospectively compared two weaning strategies, early extubation with immediate non-invasive ventilation (NIV) versus standard weaning encompassing spontaneous breathing trial (SBT), with respect to IMV duration (primary endpoint), extubation failures and reintubations, rate of tracheostomy, intensive care unit (ICU) length of stay and mortality (additional endpoints). All COVID-19 adult patients, intubated for hypoxemic ARF and subsequently extubated, were enrolled. Patients were included in two groups, early extubation followed by immediate NIV application, and conventionally weaning after passing SBT. 121 patients were enrolled and analyzed, 66 early extubated and 55 conventionally weaned after passing an SBT. IMV duration was 9 [6–11] days in early extubated patients versus 11 [6–15] days in standard weaning group (p = 0.034). Extubation failures [12 (18.2%) vs. 25 (45.5%), p = 0.002] and reintubations [12 (18.2%) vs. 22 (40.0%) p = 0.009] were fewer in early extubation compared to the standard weaning groups, respectively. Rate of tracheostomy, ICU mortality, and ICU length of stay were no different between groups. Compared to standard weaning, early extubation followed by immediate NIV shortened IMV duration and reduced the rate of extubation failure and reintubation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.