ObjectiveTo investigate the gap between real-world data and clinical research initiated by doctors in China, explore the potential reasons for this gap and collect different stakeholders’ suggestions.DesignThis qualitative study involved three types of hospital personnel based on three interview outlines. The data analysis was performed using the constructivist grounded theory analysis process.SettingSix tertiary hospitals (three general hospitals and three specialised hospitals) in Beijing, China, were included.ParticipantsIn total, 42 doctors from 12 departments, 5 information technology managers and 4 clinical managers were interviewed through stratified purposive sampling.ResultsElectronic medical record data cannot be directly downloaded into clinical research files, which is a major problem in China. The lack of data interoperability, unstructured electronic medical record data and concerns regarding data security create a gap between real-world data and research data. Updating hospital information systems, promoting data standards and establishing an independent clinical research platform may be feasible suggestions for solving the current problems.ConclusionsDetermining the causes of gaps and targeted solutions could contribute to the development of clinical research in China. This research suggests that updating the hospital information system, promoting data standards and establishing a clinical research platform could promote the use of real-world data in the future.
Background
Electronic sources (eSources) can improve data quality and reduce clinical trial costs. Our team has developed an innovative eSource record (ESR) system in China. This study aims to evaluate the efficiency, quality, and system performance of the ESR system in data collection and data transcription.
Methods
The study used time efficiency and data transcription accuracy indicators to compare the eSource and non-eSource data collection workflows in a real-world study (RWS). The two processes are traditional data collection and manual transcription (the non-eSource method) and the ESR-based source data collection and electronic transmission (the eSource method). Through the system usability scale (SUS) and other characteristic evaluation scales (system security, system compatibility, record quality), the participants’ experience of using ESR was evaluated.
Results
In terms of the source data collection (the total time required for writing electronic medical records (EMRs)), the ESR system can reduce the time required by 39% on average compared to the EMR system. In terms of data transcription (electronic case report form (eCRF) filling and verification), the ESR can reduce the time required by 80% compared to the non-eSource method (difference: 223 ± 21 s). The ESR accuracy in filling the eCRF field is 96.92%. The SUS score of ESR is 66.9 ± 16.7, which is at the D level and thus very close to the acceptable margin, indicating that optimization work is needed.
Conclusions
This preliminary evaluation shows that in the clinical medical environment, the ESR-based eSource method can improve the efficiency of source data collection and reduce the workload required to complete data transcription.
Objective: The mitotic count of gastrointestinal stromal tumors (GIST) is closely associated with the risk of planting and metastasis. The purpose of this study was to develop a predictive model for the mitotic index of local primary GIST, based on deep learning algorithm. Materials and Methods: Abdominal contrast-enhanced CT images of 148 pathologically confirmed GIST cases were retrospectively collected for the development of a deep learning classification algorithm. The areas of GIST masses on the CT images were retrospectively labelled by an experienced radiologist. The postoperative pathological mitotic count was considered as the gold standard (high mitotic count, > 5/50 high-power fields [HPFs]; low mitotic count, ≤ 5/50 HPFs). A binary classification model was trained on the basis of the VGG16 convolutional neural network, using the CT images with the training set (n = 108), validation set (n = 20), and the test set (n = 20). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated at both, the image level and the patient level. The receiver operating characteristic curves were generated on the basis of the model prediction results and the area under curves (AUCs) were calculated. The risk categories of the tumors were predicted according to the Armed Forces Institute of Pathology criteria. Results: At the image level, the classification prediction results of the mitotic counts in the test cohort were as follows: sensitivity 85.7% (95% confidence interval [
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.