Aims Systemic inflammatory response, identified by increased total leucocyte counts, was shown to be a strong predictor of mortality after transcatheter aortic valve implantation (TAVI). Yet the mechanisms of inflammation-associated poor outcome after TAVI are unclear. Therefore, the present study aimed at investigating individual inflammatory signatures and functional heterogeneity of circulating myeloid and T-lymphocyte subsets and their impact on 1 year survival in a single-centre cohort of patients with severe aortic stenosis undergoing TAVI. Methods and results One hundred twenty-nine consecutive patients with severe symptomatic aortic stenosis admitted for transfemoral TAVI were included. Blood samples were obtained at baseline, immediately after, and 24 h and 3 days after TAVI, and these were analysed for inflammatory and cardiac biomarkers. Myeloid and T-lymphocyte subsets were measured using flow cytometry. The inflammatory parameters were first analysed as continuous variables; and in case of association with outcome and area under receiver operating characteristic (ROC) curve (AUC) ≥ 0.6, the values were dichotomized using optimal cutoff points. Several baseline inflammatory parameters, including high-sensitivity C-reactive protein (hsCRP; HR = 1.37, 95% CI: 1.15-1.63; P < 0.0001) and IL-6 (HR = 1.02, 95% CI: 1.01-1.03; P = 0.003), lower counts of Th2 (HR = 0.95, 95% CI: 0.91-0.99; P = 0.009), and increased percentages of Th17 cells (HR = 1.19, 95% CI: 1.02-1.38; P = 0.024) were associated with 12 month all-cause mortality. Among postprocedural parameters, only increased post-TAVI counts of non-classical monocytes immediately after TAVI were predictive of outcome (HR = 1.03, 95% CI: 1.01-1.05; P = 0.003). The occurrence of SIRS criteria within 48 h post-TAVI showed no significant association with 12 month mortality (HR = 0.57, 95% CI: 0.13-2.43, P = 0.45). In multivariate analysis of discrete or dichotomized clinical and inflammatory variables, the presence of diabetes mellitus (HR = 3.50; 95% CI: 1.42-8.62; P = 0.006), low left ventricular (LV) ejection fraction (HR = 3.16; 95% CI: 1.35-7.39; P = 0.008), increased baseline hsCRP (HR = 5.22; 95% CI: 2.09-13.01; P < 0.0001), and low baseline Th2 cell counts (HR = 8.83; 95% CI: 3.02-25.80) were significant predictors of death. The prognostic value of the linear prediction score calculated of these parameters was superior to the Society of Thoracic Surgeons score (AUC: 0.88; 95% CI: 0.78-0.99 vs. 0.75; 95% CI: 0.64-0.86, respectively; P = 0.036). Finally, when analysing LV remodelling outcomes, ROC curve analysis revealed that low numbers of Tregs (P = 0.017; AUC: 0.69) and increased Th17/Treg ratio (P = 0.012; AUC: 0.70) were predictive of adverse remodelling after TAVI. Conclusions Our findings demonstrate an association of specific pre-existing inflammatory phenotypes with increased mortality and adverse LV remodelling after TAVI. Distinct monocyte and T-cell signatures might provide additive biomarkers to improve pre-procedural risk stratification in ...
BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis. Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017. By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).ResultsThe median age of the study population was 66.0 years, 22.7% of the patients were female. The underlying heart disease was ischemic cardiomyopathy (61.4%) with a median LVEF of 30%. Only 52.9% had received an ICD for primary prevention, most of the patients (67.3%) had advanced heart failure (NYHA class II–III) and 16.8% were in atrial fibrillation. CCI was 5 points in TV-ICD patients vs. 4 points for patients with S-ICD (p = 0.209) indicating increased morbidity. The composite endpoint occurred in 38 patients (31.9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.50, 95 % confidence interval (CI) 0.78–2.90; p = 0.229, weighted HR 0.94, 95% CI, 0.61–1.50, p = 0.777). Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders. Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Background Musclin is an activity‐stimulated and cardioprotective myokine that attenuates pathological cardiac remodeling. Musclin deficiency, in turn, results in reduced physical endurance. The aim of this study was to assess the prognostic value of circulating musclin as a novel, putative biomarker to identify patients undergoing transcatheter aortic valve implantation (TAVI) who are at a higher risk of death. Methods and Results In this study, we measured systemic musclin levels in 368 patients undergoing TAVI who were at low to intermediate clinical risk (median EuroSCORE [European System for Cardiac Operative Risk Evaluation] II: 3.5; quartile 1–quartile, 2.2%–5.3%), whereby 209 (56.8%) patients were at low and 159 (43.2%) were at intermediate risk. Median preprocedural musclin levels were 2.7 ng/mL (quartile 1–quartile 3, 1.5–4.6 ng/mL). Musclin levels were dichotomized in low (<2.862 ng/mL, n=199 [54.1%]) or high (≥ 2.862 ng/mL, n=169 [45.9%]) groups using cutoff values determined by classification and regression tree analysis. The primary end point was 1‐year overall survival. Patients with low circulating musclin levels exhibited a significantly higher prevalence of frailty, low albumin values, hypertension, and history of stroke as well as higher N‐terminal pro‐B‐type natriuretic peptide. Low musclin levels significantly predicted risk of death in univariable (hazard ratio, 1.81; 95% CI, 1.00–3.53 [ P =0.049]) and multivariable (adjusted hazard ratio, 2.45; 95% CI, 1.06–5.69 [ P =0.037]) Cox regression analyses. Additionally, low musclin levels in combination with conventional EuroSCORE II suggested improved risk stratification in patients undergoing TAVI who were at low to intermediate clinical risk into subgroups with reduced 1‐year survival rates by log‐rank test ( P for trend=0.003). Conclusions Circulating musclin is an independent predictor of 1‐year overall survival in patients undergoing TAVI. Combined with EuroSCORE II, circulating musclin might help to improve prediction of mortality in patients undergoing TAVI who are at low to intermediate clinical risk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.