Exposure of healthcare providers to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a significant safety concern during the coronavirus disease 2019 (COVID-19) pandemic, requiring contact/droplet/airborne precautions. Because of global shortages, limited availability of personal protective equipment (PPE) has motivated the development of barrier-enclosure systems, such as aerosol boxes, plastic drapes, and similar protective systems. We examined the available evidence and scientific publications about barrier-enclosure systems for airway management in suspected/ confirmed COVID-19 patients. MEDLINE/Embase/Google Scholar databases (from December 1, 2019 to May 27, 2020) were searched for all articles on barrier enclosures for airway management in COVID-19, including references and websites. All sources were reviewed by a panel of experts using a Delphi method with a modified nominal group technique. Fiftytwo articles were reviewed for their results and level of evidence regarding barrier device feasibility, advantages, protection against droplets and aerosols, effectiveness, safety, ergonomics, and cleaning/disposal. The majority of analysed papers were expert opinions, small case series, technical descriptions, small-sample simulation studies, and pre-print proofs. The use of barrier-enclosure devices adds to the complexity of airway procedures with potential adverse consequences, especially during airway emergencies. Concerns include limitations on the ability to perform airway interventions and the aid that can be delivered by an assistant, patient injuries, compromise of PPE integrity, lack of evidence for added protection of healthcare providers (including secondary aerosolisation upon barrier removal), and lack of cleaning standards. Enclosure barriers for airway management are no substitute for adequate PPE, and their use should be avoided until adequate validation studies can be reported.
The coronavirus disease 2019 (COVID-19) disease, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), often results in severe hypoxemia requiring airway management. Because SARS-CoV-2 virus is spread via respiratory droplets, bag-mask ventilation, intubation, and extubation may place health care workers (HCW) at risk. While existing recommendations address airway management in patients with COVID-19, no guidance exists specifically for difficult airway management. Some strategies normally recommended for difficult airway management may not be ideal in the setting of COVID-19 infection. To address this issue, the Society for Airway Management (SAM) created a task force to review existing literature and current practice guidelines for difficult airway management by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. The SAM task force created recommendations for the management of known or suspected difficult airway in the setting of known or suspected COVID-19 infection. The goal of the task force was to optimize successful airway management while minimizing exposure risk. Each member conducted a literature review on specific clinical practice section utilizing standard search engines (PubMed, Ovid, Google Scholar). Existing recommendations and evidence for difficult airway management in the COVID-19 context were developed. Each specific recommendation was discussed among task force members and modified until unanimously approved by all task force members. Elements of Appraisal of Guidelines Research and Evaluation (AGREE) Reporting Checklist for dissemination of clinical practice guidelines were utilized to develop this statement. Airway management in the COVID-19 patient increases HCW exposure risk. Difficult airway management often takes longer and may involve multiple procedures with aerosolization potential, and strict adherence to personal protective equipment (PPE) protocols is mandatory to reduce risk to providers. When a patient’s airway risk assessment suggests that awake tracheal intubation is an appropriate choice of technique, and procedures that may cause increased aerosolization of secretions should be avoided. Optimal preoxygenation before induction with a tight seal facemask may be performed to reduce the risk of hypoxemia. Unless the patient is experiencing oxygen desaturation, positive pressure bag-mask ventilation after induction may be avoided to reduce aerosolization. For optimal intubating conditions, patients should be anesthetized with full muscle relaxation. Videolaryngoscopy is recommended as a first-line strategy for airway management. If emergent invasive airway access is indicated, then we recommend a surgical technique such as scalpel-bougie-tube, rather than an aerosolizing generating procedure, such as transtracheal jet ventilation. This statement represents recommendations by the SAM task force for the difficult airway management of adults with COVID-19 with the goal to optimize successful airway management while minimizing the risk of clinician exposure.
Tracheal intubation via laryngeal exposure has evolved over the past 150 years and has greatly expanded in the last decade with the introduction and development of newer, more sophisticated optical airway devices. The introduction of indirect and video-assisted laryngoscopes has significantly impacted airway management as evidenced by the presence of these devices in the majority of published difficult airway algorithms. However, it is quite possible that many airway managers do not have a thorough comprehension of how these devices actually function, an understanding that is vital not only for their use but also for assessing the devices' limitations. This article discusses the development of video laryngoscopy, how the video laryngoscope works, and the impact of video laryngoscopy on difficult airway management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.