An increased lactate level is related to increased mortality in subpopulations of critically ill patients. The aim of this study was to investigate whether lactate was related to mortality in an emergency department (ED) setting of undifferentiated medical patients. All adult patients admitted from March 2009 to August 2011 to a medical ED with lactate measured within 6 h after arrival were studied. Lactate was stratified into 1-mmol/l intervals and analysed in a multivariate logistic regression analysis. A total of 5317 patients were included, 46.9% men, median age 71 years (5-95% percentiles 25-90 years). The median lactate level was 1.2 mmol/l (5-95% percentiles 0.6-3.8 mmol/l, range 0.2-22 mmol/l). Lactate was associated with 10-day mortality independent of age, comorbidity and presence of hypotension, with an odds ratio of 1.54 (95% confidence interval 1.44-1.63) per 1 mmol/l increase. Lactate is an independent predictor of 10-day mortality among patients admitted to a medical ED.
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
BackgroundThe combination of low‐dose local anesthesia and lipophilic opioids such as fentanyl is established as a standard solution for labor epidural analgesia. Fentanyl increases efficacy, but may have negative effects on the neonate in terms of reduced neonatal neurologic and adaptive capacity scores and breast feeding. We hypothesized that addition of adrenaline 2 μg/mL to a solution of bupivacaine 1 mg/mL and fentanyl 2 μg/mL would reduce the systemic uptake of fentanyl, resulting in reduced serum fentanyl in the fetus at birth.MethodsForty‐one nulliparous women requesting epidural analgesia were randomized to epidural analgesia with or without adrenaline. Blood samples were drawn from the mother with regular intervals, and at delivery. An umbilical vein blood sample (used as a proxy for fetal exposure) was drawn after clamping.ResultsThere were no significant differences between the groups in fentanyl concentrations in the umbilical vein and maternal serum at birth. There was a significantly lower mean area under the maternal serum‐concentration curve for the first 2 hours of treatment in the adrenaline group (mean difference 0.161 nmol h/L [0.034; 0.289], P = .015), implying slower systemic uptake in the adrenaline group initially. There were no significant differences in treatment duration, motor block, Apgar scores, umbilical pH and base excess, or mode of delivery.ConclusionsThe addition of adrenaline to an epidural solution containing fentanyl lowered maternal systemic serum fentanyl concentration during the first 2 hours, but did not lower serum fentanyl concentration in the umbilical vein and mother at delivery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.