To reduce the effect of estimation position angle error caused by mutual inductance on sensorless control of switched reluctance motor (SRM) in clear command channel mode, a SRM rotor position estimation method is presented. Using this method, the effect of mutual inductance can be eliminated without measuring mutual inductance. First, different working states are analysed. When working at single-phase excitation, mutual inductance can be ignored, inductance model method is used to estimate the position angle. When working at two-phase excitation situation, mutual inductance is non-zero, based on flux linkage-difference a new method is used to eliminate mutual inductance influence. Finally, the proposed method is verified by experiments. Experiment results show that compared with the mutual inductance ignored methods, the proposed method has higher estimation accuracy. This method can realise stable and reliable running of SRM sensorless control in wider speed range.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.