TFBC presented the highest pH and solubility, but showed similar VC to GFB and AH Plus. GFB showed proper physicochemical properties. Micro-computed tomography complements the physicochemical analysis of endodontic sealers.
Aim
To assess the effect of immersion in distilled water or phosphate‐buffered saline (PBS) on the solubility, volumetric change and presence of voids of calcium silicate‐based root canal sealers (TotalFill BC, Sealer Plus BC and Bio‐C), in comparison with the gold standard epoxy resin‐based sealer (AH Plus).
Methodology
All properties were evaluated after immersion in distilled water or PBS. Solubility was determined by the percentage of mass loss, whereas volumetric change and presence of voids were evaluated by micro‐computed tomography, after 7 days of immersion. The volumetric change and percentage of voids between the baseline (after setting) and the experimental period were calculated. Statistical analysis was performed using one‐way anova and Tukey's or Student's t‐tests (α = 0.05).
Results
The calcium silicate‐based sealers had significantly greater solubility and volumetric loss than AH Plus, after immersion in distilled water or PBS (P < 0.05). Bio‐C had the greatest solubility (P < 0.05), followed by TotalFill BC and Sealer Plus BC, which were similar (P > 0.05). Regarding the volumetric change, AH Plus had a volume increase, with similar values in distilled water and PBS (P > 0.05). TotalFill BC, Sealer Plus BC and Bio‐C had a similar volumetric change (P > 0.05). The calcium silicate‐based materials had the greatest solubility and volume loss after immersion in distilled water (P < 0.05). There was no difference in the percentage of voids amongst the sealers, before and after immersion in distilled water or PBS (P > 0.05).
Conclusions
TotalFill BC, Sealer Plus BC and Bio‐C had significantly greater solubility and volumetric loss than AH Plus. Although storage in PBS significantly reduced the solubility and volumetric change of calcium silicate‐based sealers, their solubility remained above that recommend by ISO 6876. All the sealers evaluated had low and similar voids, even after immersion in distilled water or PBS.
Objective To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods.Material and Methods
7
Results The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in comparison with MTA (p<0.05). With regard to volumetric change, the tested materials were similar (p>0.05) at 7 days. At 30 days, they presented similar solubility. BIO and MTA showed higher dimensional stability than ZOE (p<0.05). ZOE and BIO showed higher filling ability (p<0.05).Conclusions ZOE presented a higher dimensional change, and BIO had greater solubility after 7 days. BIO presented filling ability and dimensional stability, but greater volumetric change than MTA after 30 days. Micro-CT can provide important data on the physicochemical properties of materials complementing conventional tests.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.