The rapid detection of complex (MTUBC) in clinical samples is essential for successful treatment. New techniques such as real-time PCR have been developed in order to facilitate rapid diagnosis, but their sensitivity is low in extrapulmonary specimens, due to the low bacillary load in such samples. A next-generation assay has recently been developed to try to overcome this limitation. The aim of this study was to analyze the effectiveness of the Xpert MTB/RIF Ultra (GX-Ultra) for the detection of MTUBC DNA in 108 smear-negative extrapulmonary specimens that were MTUBC culture positive. In addition, 40 extrapulmonary culture-negative samples and 20 samples with nontuberculous mycobacteria were tested to evaluate the specificity of the assay. All samples were collected between May 1999 and May 2017. The GX-Ultra detected DNA of MTUBC in 82 extrapulmonary specimens that were MTUBC culture positive (75.9% sensitivity; 95% confidence interval [CI], 66.6 to 83.4%). The assay was negative for all clinical specimens that were MTUBC culture negative and the samples with nontuberculous mycobacteria (100% specificity). Furthermore, two (1.8%) samples presented mutations related to rifampin resistance. The highest sensitivity was obtained in samples of lymph nodes (94.1%) and nonsterile fluids (93.7%), followed by tissue specimens (86.6%), stool material (80%), abscess aspirates (64.7%), and sterile fluids (60.5%). Pleural fluids, one of the least optimal samples for detecting DNA of MTUBC, were GX-Ultra positive in 10/21 (47.6%) of cases. In summary, GX-Ultra showed excellent specificity and high sensitivity in paubacillary specimens, making it a useful tool for rapid diagnosis of extrapulmonary tuberculosis.
The ability of MALDI-TOF for the identification of nontuberculous mycobacteria (NTM) has improved recently thanks to updated databases and optimized protein extraction procedures. Few multicentre studies on the reproducibility of MALDI-TOF have been performed so far, none on mycobacteria. The aim of this study was to evaluate the reproducibility of MALDI-TOF for the identification of NTM in 15 laboratories in 9 European countries. A total of 98 NTM clinical isolates were grown on Löwenstein-Jensen. Biomass was collected in tubes with water and ethanol, anonymized and sent out to the 15 participating laboratories. Isolates were identified using MALDI Biotyper (Bruker Daltonics). Up to 1330 MALDI-TOF identifications were collected in the study. A score ≥ 1.6 was obtained for 100% of isolates in 5 laboratories (68.2–98.6% in the other). Species-level identification provided by MALDI-TOF was 100% correct in 8 centres and 100% correct to complex-level in 12 laboratories. In most cases, the misidentifications obtained were associated with closely related species. The variability observed for a few isolates could be due to variations in the protein extraction procedure or to MALDI-TOF system status in each centre. In conclusion, MALDI-TOF showed to be a highly reproducible method and suitable for its implementation for NTM identification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.