Fluxometria da artéria torácica interna esquerda na revascularização da artéria descendente anterior com e sem circulação extracorpóreaFlowmetry of left internal thoracic artery graft to left anterior descending artery: comparison between on-pump and off-pump surgery Abstract Background: Off-pump coronary bypass grafting (OPCAB) has become a widely used technique. Coronary flowmetry is the most common method employed to assess graft patency, nevertheless, few studies compare flow patterns between ONCAB and OPCAB surgery. The objective of this study was to compare flowmetry data in left internal mammary artery grafts bypasses to the left anterior descendent artery.Methods: From March to September of 2010, thirty-five consecutive, non-randomized patients underwent CABG and were retrospectively evaluated. Ten patients were located on group A (On Pump), and twenty-five on group B (Off Pump). The mean graft flow (MGF), pulsatile index (PI) and diastolic filling (DF) were obtained using Transit Time Flowmetry (TTFM). The Fisher exact test, and Mann Whitney test were used, and a P value of < 0.05 was considered to indicate statistical significance.Results: There were no deaths, AMI, re-interventions or PTCA in a 30-day period. The number of bypasses performed per patient was 2.3 ± 0.8 in the OPCAB group, and 2.2 ± 0.6 in the ONCAB group, with no significant difference (P=0.10). The median of mean flow was 23 ml/min on group A, and 25 ml/min on group B (P=0.34). Diastolic filling percentage was 56% on group A, and 56.9% on group B (P=0.86). Pulsatile Index was 2.3 on group A, and 2.2 on group B (P=0.82).Conclusions: There was no difference between TTFM values (MF, PI and DF) in patients operated with or without cardiopulmonary bypass. Rev Bras Cir Cardiovasc 2012;27(2):283-9 Descriptors
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.