ObjectivesIntracranial aneurysm (IA) is the main cause of subarachnoid hemorrhages. Time-of-flight (TOF) magnetic resonance angiography (MRA) at 1.5 T or 3 T magnetic resonance imaging (MRI) is a well-established method for the diagnosis of IA. The aim of this prospective study was to evaluate the performance of a modern 0.55 T MRI in the diagnosis of IAs in comparison to digital subtraction angiography (DSA) as a standard of reference.Materials and MethodsSeventeen patients with suspicion of single or multiple IAs underwent TOF MRA at 0.55 T MRI 1 day before DSA. Two neuroradiologists independently measured the aneurysm neck, width, and height on 0.55 T, 1.5 T, and 3 T 3D-TOF MRA source images and 2D/3D rotational angiography. The main analysis assessed the intermodality agreement between 0.55 T TOF MRA and DSA using Bland-Altman plots, a Wilcoxon test, and the intraclass correlation coefficient (ICC). In a secondary analysis, aneurysm dimensions were compared between 0.55 T TOF MRA and 1.5/3 T TOF MRA. Interreader agreement was evaluated by ICC. A third neuroradiologist blinded to patient history screened 0.55 T TOF MRA data sets of the aforementioned 17 patients and 15 additional healthy patients for the presence and location of aneurysms.ResultsA total of 19 aneurysms in 16 patients were identified in both 0.55 T MRA and DSA. Measurements of the 2 nonblinded readers showed no significant differences between 0.55 T TOF MRA and DSA in the overall aneurysm size (calculated as the mean from height/width/neck) (P = 0.178), as well as in the mean width (P = 0.778) and neck values (P = 0.190). The mean height was significantly larger in 0.55 T TOF MRA in comparison to DSA (P = 0.020). Intermodality (1.5/3 T TOF MRA) and interrater agreement were excellent (ICC > 0.94). Of the 32 data sets of patients with and without IA, the blinded reader detected all aneurysms correctly by using 0.55 T images.ConclusionsTOF-MRA acquired with a modern 0.55 T MRI is a reliable tool for the detection and initial assessment of IAs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.