Electrocardiograms (ECG) are universally used to measure the electrical activity of the heart; however, variations in recording techniques and/or subject demographics can affect ECG interpretation. In this study, we investigated variables that are likely to influence ECG metric measurements in cardiovascular research, including recording technique, use of anesthesia, and animal model characteristics. Awake limb lead ECG recordings were collected in vivo from adult guinea pigs using a platform ECG system, while recordings in anesthetized animals were performed using both a platform and needle ECG system. We report significant heterogeneities in ECG metric values that are attributed to methodological differences (e.g., ECG lead configuration, ECG recording platform, presence or absence of anesthesia) that persist even within the same cohort of animals. Further, we report that variability in animal demographics is preserved in vivo ECG recordings—with animal age serving as a significant contributor, while sex-specific influences were less pronounced. Methodological approaches and subject demographics should be fully considered when interpreting ECG values in animal models, comparing datasets between studies, or developing artificial intelligence algorithms that utilize an ECG database.
Highlighting the importance of sex as a biological variable, we recently reported sex differences in guinea pig in vivo electrocardiogram (ECG) measurements. However, substantial inconsistencies exist in this animal model - with conflicting reports of sex-specific differences in cardiac electrophysiology observed in vivo versus in vitro. Herein, we evaluated whether sexual dimorphism persists between in vivo and ex vivo preparations, using an isolated intact heart preparation. Pseudo-ECG recordings were collected in conjunction with dual optical mapping of transmembrane voltage and intracellular calcium from Langendorff-perfused hearts. In contrast to our in vivo results, we did not observe sex-specific differences in ECG parameters collected from isolated hearts. Further, we observed significant age-specific differences in action potential duration (APD) and Ca2+ transient duration (CaD) during both normal sinus rhythm (NSR) and in response to dynamic pacing; but, only a modest sex-specific difference in CaD30. Similarly, the alternans fluctuation coefficient, conduction velocity during sinus rhythm or in response to pacing, and electrophysiology parameters (atrioventricular nodal effective refractory period, Wenckebach cycle length) were comparable between males and females. Results of our study suggest that the observed sex-specific differences in in vivo ECG parameters from guinea pigs are largely negated in ex vivo isolated heart preparations; although, age-specific patterns are prevalent. To assess sex as a biological variable in cardiac electrophysiology, a comprehensive approach may be necessary using both in vitro measurements from cardiomyocyte or intact heart preparations with secondary follow-up in vivo studies.
Background: Cardiac optical mapping is an imaging technique that measures fluorescent signals across a cardiac preparation. Dual optical mapping of voltage-sensitive and calcium-sensitive probes allow for simultaneous recordings of cardiac action potentials and intracellular calcium transients with high spatiotemporal resolution. The analysis of these complex optical data sets re both time intensive and technically challenging; as such, we have developed a software package for semi-automated image processing and analysis. Herein, we report an updated version of our software package (KairoSight-3.0) with updated features to fully characterize cardiac parameters using optical signals. Methods: To collect datasets to test software validity and applicability, we used Langendorff-perfused heart preparations to record transmembrane voltage and intracellular calcium signals from the epicardial surface. Isolated hearts from guinea pigs and rats were loaded with a potentiometric dye (RH237) and/or calcium indicator dye (Rhod-2AM) and fluorescent signals were acquired. We used Python 3.8.5 programming language to develop the KairoSight-3.0 software. Cardiac maps were validated with a user-specified manual mapping approach using MATLAB scripts. Results: Manual maps of action potential duration (30 or 80% repolarization), calcium transient duration (30 or 80% reuptake), action potential and calcium transient alternans were constituted to validate the accuracy of software-generated maps. Manual and software maps had high accuracy, with >97% of manual and software values falling within 10 ms of each other and >75% within 5 ms for action potential duration and calcium transient duration measurements (n=1000-2000 pixels). Further, our software package includes additional cardiac metric measurement tools to analyze signal-to-noise ratio, conduction velocity, action potential and calcium transient alternans, and action potential-calcium transient coupling time to produce physiologically meaningful optical maps. Conclusions: KairoSight-3.0 has enhanced capabilities to perform measurements of cardiac electrophysiology, calcium handling, and the excitation-contraction coupling with satisfactory accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.