After introduction of the protoporphyrin IX-triplet state lifetime technique as a new method to measure mitochondrial oxygen tension in vivo, the development of a clinical monitor was started. This monitor is the “COMET”, an acronym for Cellular Oxygen METabolism. The COMET is a non-invasive electrically powered optical device that allows measurements on the skin. The COMET is easy to transport, due to its lightweight and compact size. After 5-aminolevulinic acid application on the human skin, a biocompatible sensor enables detection of PpIX in the mitochondria. PpIX acts as a mitochondrially located oxygen-sensitive dye. Three measurement types are available in the touchscreen-integrated user interface, ‘Single’, ‘Interval’ and ‘Dynamic measurement’. COMET is currently used in several clinical studies in our institution. In this first description of the COMET device we show an incidental finding during neurosurgery. To treat persisting intraoperative hypertension a patient was administered clonidine, but due to rapid administration an initial phase of peripheral vasoconstriction occurred. Microvascular flow and velocity parameters measured with laser-doppler (O2C, LEA Medizintechnik) decreased by 44 and 16% respectively, but not the venous-capillary oxygen saturation. However, mitochondrial oxygen tension in the skin detected by COMET decreased from a steady state of 48 to 16 mmHg along with the decrease in flow and velocity. We conclude that COMET is ready for clinical application and we see the future for this bedside monitor on the intensive care, operating theater, and testing of mitochondrial effect of pharmaceuticals.
BackgroundThe protoporphyrin IX-triplet state lifetime technique (PpIX-TSLT) is proposed as a potential clinical non-invasive tool to monitor mitochondrial function. This technique has been evaluated in several animal studies. Mitochondrial respirometry allows measurement in vivo of mitochondrial oxygen tension (mitoPO2) and mitochondrial oxygen consumption (mitoVO2) in skin. This study describes the first use of a clinical prototype in skin of humans.MethodsThe clinical prototype was tested in 30 healthy volunteers. A self-adhesive patch containing 2 mg 5-aminolevulinic acid (ALA) was applied on the skin of the anterior chest wall (sternal) for induction of mitochondrial protoporphyrin IX and was protected from light for 5 h. MitoPO2 was measured by means of oxygen-dependent delayed fluorescence of protoporphyrin IX. MitoVO2 was determined by dynamic mitoPO2 measurements on the primed skin, while locally blocking oxygen supply by applying local pressure with the measurement probe. MitoPO2 was recorded before and during a 60-s period of compression of the microcirculation, at an interval of 1 Hz. Oxygen consumption (i.e. the local oxygen disappearance rate) was calculated from the decay of the mitoPO2 slope.ResultsOxygen-dependent delayed fluorescence measurements were successfully performed in the skin of 27 volunteers. The average value (± SD) of mitoPO2 was 44 ± 17 mmHg and mean mitoVO2 values were 5.8 ± 2.3 and 6.1 ± 1.6 mmHg s-1 at a skin temperature of 34°C and 40°C, respectively. No major discomfort during measurement and no long-term dermatological abnormalities were reported in a survey performed 1 month after measurements.ConclusionThese results show that the clinical prototype allows measurement of mitochondrial oxygenation and oxygen consumption in humans. The development of this clinically applicable device offers opportunities for further evaluation of the technique in humans and the start of first clinical studies.
Measurement of tissue oxygenation is a complex task and various techniques have led to a wide range of tissue PO(2) values and contradictory results. Tissue is compartmentalized in microcirculation, interstitium and intracellular space and current techniques are biased towards a certain compartment. Simultaneous oxygen measurements in various compartments might be of great benefit for our understanding of determinants of tissue oxygenation. Here we report simultaneous measurement of microvascular PO(2) (μPO(2) ) and mitochondrial PO(2) (mitoPO(2) ) in rats. The μPO(2) measurements are based on oxygen-dependent quenching of phosphorescence of the near-infrared phosphor Oxyphor G2. The mitoPO(2) measurements are based on oxygen-dependent quenching of delayed fluorescence of protoporphyrin IX (PpIX). Favorable spectral properties of these porphyrins allow simultaneous measurement of the delayed luminescence lifetimes. A dedicated fiber-based time-domain setup consisting of a tunable pulsed laser, 2 red-sensitive gated photomultiplier tubes and a simultaneous sampling data-acquisition system is described in detail. The absence of cross talk between the channels is shown and the feasibility of simultaneous μPO(2) and mitoPO(2) measurements is demonstrated in rat liver in vivo. It is anticipated that this novel approach will greatly contribute to our understanding of tissue oxygenation in physiological and pathological circumstances.
IntroductionAlthough mitochondrial dysfunction is proposed to be involved in the pathophysiology of sepsis, conflicting results are reported. Variation in methods used to assess mitochondrial function might contribute to this controversy. A non-invasive method for monitoring mitochondrial function might help overcome this limitation. Therefore, this study explores the possibility of in vivo monitoring of mitochondrial oxygen tension (mitoPO2) and local mitochondrial oxygen consumptionin in an endotoxin-induced septic animal model.MethodsAnimals (rats n = 28) were assigned to a control group (no treatment), or to receive lipopolysaccharide without fluid resuscitation (LPS-NR) or lipopolysaccharide plus fluid resuscitation (LPS-FR). Sepsis was induced by intravenous LPS injection (1.6 mg/kg during 10 min), fluid resuscitation was performed by continuous infusion of a colloid solution, 7 ml kg−1 h−1 and a 2-ml bolus of the same colloid solution. MitoPO2 and ODR were measured by means of the protoporphyrin IX-triplet state lifetime technique (PpIX-TSLT). Kinetic aspects of the drop in mitoPO2 were recorded during 60s of skin compression. ODR was derived from the slope of the mitoPO2 oxygen disappearance curve. Measurements were made before and 3 h after induction of sepsis.ResultsAt baseline (t0) all rats were hemodynamically stable. After LPS induction (t1), significant (p < 0.05) hemodynamic changes were observed in both LPS groups. At t0, mitoPO2 and ODR were 59 ± 1 mmHg, 64 ± 3 mmHg, 68 ± 4 mmHg and 5.0 ± 0.3 mmHg s−1, 5.3 ± 0.5 mmHg s−1, 5.7 ± 0.5 mmHg s−1 in the control, LPS-FR and LPS-NR groups, respectively; at t1 these values were 58 ± 5 mmHg, 50 ± 2.3 mmHg, 30 ± 3.3 mmHg and 4.5 ± 0.5 mmHg s−1, 3.3 ± 0.3 mmHg s−1, 1.8 ± 0.3 mmHg s−1, respectively. At t1, only mitoPO2 showed a significant difference between the controls and LPS-NR. In contrast, at t1 both LPS groups showed a significantly lower ODR compared to controls.ConclusionThese data show the feasibility to monitor alterations in mitochondrial oxygen consumption in vivo by PpIX-TSLT in a septic rat model. These results may contribute to the development of a clinical device to monitor mitochondrial function in the critically ill.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.