Objectives
To measure and compare rectal temperature measurement with and without thermometer protective sheaths. To survey veterinary practices regarding thermometer use and disinfection.
Materials and Methods
Thermometers were validated with and without protective sheaths for accuracy and repeatability in a water bath with a high precision thermometer as reference. Then, the rectal temperature of 500 dogs was measured with and without protective sheaths in randomised order. The difference in temperature measured by the two methods was analysed with a generalised linear model with order of temperature measurement, life stage, dog size, body condition, level of consciousness, class of temperature and operator as explanatory variables. Practical thermometer use and disinfection was surveyed by online questionnaire.
Results
In the pre‐clinical phase, study thermometers recorded average temperature differences of −0.05 ± 0.07°C (mean ± SD) and −0.03 ± 0.08°C with and without sheath, respectively and the coefficients of variation ranged from 0.1 to 0.5% with and without sheath. In the clinical study, temperatures measured with and without sheaths differed by less than ±0.2°C for 92% of the measurements. None of the explanatory variables were associated with the observed differences. Twenty‐five percent of survey respondents were aware of the guidelines for disinfection of thermometers.
Clinical Significance
Thermometer protective sheaths do not affect the measurement of canine rectal temperature in the clinic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.